{"id":10171,"date":"2019-07-08T18:38:42","date_gmt":"2019-07-08T18:38:42","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=10171"},"modified":"2023-12-21T15:22:13","modified_gmt":"2023-12-21T15:22:13","slug":"c2564-bizhub-554e-454e-2","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c2564-bizhub-554e-454e-2","title":{"rendered":"C2564 (bizhub 554e\/454e)"},"content":{"rendered":"\n<p>Contents <\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>\nTrouble type<\/td><td>\nBlack TCR sensor failure<\/td><\/tr><tr><td>\nTrouble code<\/td><td>\nC2564<\/td><\/tr><tr><td>\nRank<\/td><td>\nB<\/td><\/tr><tr><td>\nDetection timing<\/td><td>\nTCR sensor automatic adjustment does not function \nproperly, failing to adjust to an appropriate value.<\/td><\/tr><tr><td>\nTrouble isolation<\/td><td>\n&#8211;<\/td><\/tr><tr><td>\nRelevant electrical parts<\/td><td>\u2022 Developing unit  <br>\u2022 Front side board (FRB)  <br>\u2022 Printer control board  (PRCB) <\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>\n&nbsp;\n(2)Procedure\n\n\n\n\n<\/p>\n\n\n\n<table class=\"wp-block-table\"><thead><tr><td>\nStep<\/td><td>\nAction<\/td><td>\nControl signal<\/td><td>\nLocation of electrical \ncomponents<\/td><\/tr><\/thead><tbody><tr><td>\n1<\/td><td>\nReinstall developing unit<\/td><td>\n&#8211;<\/td><td>\n&#8211;<\/td><\/tr><tr><td>\n2<\/td><td>\nCheck the connector between developing unit-FRB CN13 \nfor proper connection and correct as necessary.<\/td><td>\n&#8211;<\/td><td>\n&#8211;<\/td><\/tr><tr><td>\n3<\/td><td>\nCheck the connector between FRB CN1, CN3-PRCB CN7, \nCN9 for proper connection and correct as necessary.<\/td><td>\n&#8211;<\/td><td>\n&#8211;<\/td><\/tr><tr><td>\n4<\/td><td> <a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub454eService\/D0001131346\/D0001131346.html\">Replace the developing unit<\/a>Developer 554e\/454e (Part# A2XN03D)<\/td><td>\n&#8211;<\/td><td>\n&#8211;<\/td><\/tr><tr><td>\n5<\/td><td> <a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub454eService\/D0001131585\/D0001131585.html\">Replace FRB<\/a>FRB (Part# A61FH00500)<\/td><td>\n&#8211;<\/td><td>\n&#8211;<\/td><\/tr><tr><td>\n6<\/td><td> <a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub454eService\/D0001131590\/D0001131590.html\">Replace PRCB<\/a>PRCB (Part# 554e A61DH00101 454e A61EH00101)<\/td><td>\n&#8211;<\/td><td>\n&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li> Link to the layout drawings for related parts by  each trouble code (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub454eService\/D0001199250\/D0001199250.html\">S.59.  C2414, C2558, C2564<\/a>)<\/li><\/ul>\n\n\n\n<p>\n\n\n\nDocument Information\n\n\nID\nD0001134355\nRevise ID\nR000003<\/p>\n\n\n\n<p>lease review all Part Numbers for accuracy and current version.<\/p>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub454eService\/D0001134355\/D0001134355.html\">K.3.7.7<\/a> (Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type Black TCR sensor failure Trouble code C2564 Rank B Detection timing TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value. Trouble isolation &#8211; Relevant electrical parts \u2022 Developing unit \u2022 Front side board (FRB) \u2022 Printer control board (PRCB) &nbsp; (2)Procedure Step Action Control signal Location &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c2564-bizhub-554e-454e-2\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C2564 (bizhub 554e\/454e)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[922],"epkb_post_type_1_tag":[],"class_list":["post-10171","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c2-554e-454e-trouble-code"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/10171","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=10171"}],"version-history":[{"count":3,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/10171\/revisions"}],"predecessor-version":[{"id":11412,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/10171\/revisions\/11412"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=10171"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=10171"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=10171"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}