{"id":10197,"date":"2019-07-08T19:16:18","date_gmt":"2019-07-08T19:16:18","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=10197"},"modified":"2023-12-21T15:19:17","modified_gmt":"2023-12-21T15:19:17","slug":"c3201-bizhub-554e-454e","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c3201-bizhub-554e-454e","title":{"rendered":"C3201 (bizhub 554e\/454e)"},"content":{"rendered":"\n<p>Contents <\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>\nTrouble type<\/td><td>\nFusing motor failure to turn<\/td><\/tr><tr><td>\nTrouble code<\/td><td>\nC3201<\/td><\/tr><tr><td>\nRank<\/td><td>\nB<\/td><\/tr><tr><td>\nDetection timing<\/td><td>\nThe motor lock signal remains HIGH for a \npredetermined continuous period of time while the motor is \nturning.<\/td><\/tr><tr><td>\nTrouble isolation<\/td><td>\n&#8211;<\/td><\/tr><tr><td>\nRelevant electrical parts<\/td><td> \u2022 Fusing motor (M3)  <br> \u2022 Printer control board  (PRCB) <\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>\n&nbsp;\n(2)Procedure\n\n\n\n\n<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical components<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td>Check the connector between M3-PRCB CN2 for proper connection and correct as necessary.<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>2<\/td><td>Check the loading status of the fusing unit drive, and correct the error as necessary.<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>3<\/td><td>M3 operation check<\/td><td>PRCB CN2-9 (REM)PRCB CN2-12 (LOCK)<\/td><td>bizhub 554e 22-Jbizhub 454e 21-J<\/td><\/tr><tr><td>4<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub454eService\/D0001131626\/D0001131626.html\">Replace M3<\/a>&nbsp;(Part# A161M10300)<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>5<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub454eService\/D0001131590\/D0001131590.html\">Replace PRCB<\/a>&nbsp;(554e Part# A61EH00101 \/ 454e Part# A61DH00101)<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub454eService\/D0001135323\/D0001135323.html\">N.1. bizhub 554e\/454e<\/a>)<\/li><li>Link to the layout drawings for related parts by each trouble code (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub454eService\/D0001199264\/D0001199264.html\">S.67. C3201, C3202<\/a>)<\/li><\/ul>\n\n\n\n<p>\n\n\n\nDocument Information\n\n\nID\nD0001134367\nRevise ID\nR000003<\/p>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub454eService\/D0001134367\/D0001134367.html\">K.3.8.3<\/a> (Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type Fusing motor failure to turn Trouble code C3201 Rank B Detection timing The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning. Trouble isolation &#8211; Relevant electrical parts \u2022 Fusing motor (M3) \u2022 Printer control board (PRCB) &nbsp; (2)Procedure Step Action Control signal Location &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c3201-bizhub-554e-454e\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C3201 (bizhub 554e\/454e)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[923],"epkb_post_type_1_tag":[],"class_list":["post-10197","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c3-554e-454e-trouble-code"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/10197","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=10197"}],"version-history":[{"count":3,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/10197\/revisions"}],"predecessor-version":[{"id":12514,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/10197\/revisions\/12514"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=10197"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=10197"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=10197"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}