{"id":10320,"date":"2019-07-08T20:24:06","date_gmt":"2019-07-08T20:24:06","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=10320"},"modified":"2023-12-21T15:17:23","modified_gmt":"2023-12-21T15:17:23","slug":"c3b03-bizhub-554e-454e","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c3b03-bizhub-554e-454e","title":{"rendered":"C3B03 (bizhub 554e\/454e)"},"content":{"rendered":"\n<p>Contents<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>IH malfunction (monitor)<\/td><\/tr><tr><td>Trouble code<\/td><td>C3B03<\/td><\/tr><tr><td>Rank<\/td><td>A<\/td><\/tr><tr><td>Detection timing<\/td><td>&lt;bizhub 554e&gt;<\/td><td>Though the IH heater is OFF, mechanically, the ON status is detected. (Malfunction of IH heater operation)<\/td><\/tr><tr><td>Trouble isolation<\/td><td>\u2013<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>\u2022 Fusing unit&nbsp;<br>\u2022 IH coil unit (IHC)&nbsp;<br>\u2022 IH magnetic erasing board (IHMEB)&nbsp;<br>\u2022 Printer control board (PRCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>&nbsp; (2)Procedure<\/p>\n\n\n\n<table class=\"wp-block-table\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical components<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td>Check the fusing unit for correct installation (whether it is secured in position).<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>2<\/td><td>Check the open\/close operation of the upper right door.<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>3<\/td><td>Check the fusing unit, IHC, IHPU, IHMEB and PRCB for proper connection and correct or change as necessary.<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>4<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub454eService\/D0001131367\/D0001131367.html\">Replace the fusing unit<\/a>Fusing Unit (Part# 545e A2XKR71022 454e A4FJR70322)<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>5<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub454eService\/D0001131565\/D0001131565.html\">Replace IHC<\/a><\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>6<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub454eService\/D0001131609\/D0001131609.html\">Replace IHPU<\/a>IHPU (Part# 554e 100v A61DM40A00 230v A61DM40B00)<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>7<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub454eService\/D0001131607\/D0001131607.html\">Replace IHMEB<\/a>IHMEB (Part# 554e A2XKH00A00)<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>8<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub454eService\/D0001131590\/D0001131590.html\">Replace PRCB<\/a>PRCB (Part# 554e A61DH00101 454e A61EH00101)<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the layout drawings for related parts by each trouble code (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub454eService\/D0001199276\/D0001199276.html\">S.79. C3B02, C3B03<\/a>)<\/li><\/ul>\n\n\n\n<p>Document Information ID D0001134383 Revise ID R000003<\/p>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub454eService\/D0001134383\/D0001134383.html\">K.3.8.11<\/a>&nbsp;(Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type IH malfunction (monitor) Trouble code C3B03 Rank A Detection timing &lt;bizhub 554e&gt; Though the IH heater is OFF, mechanically, the ON status is detected. (Malfunction of IH heater operation) Trouble isolation \u2013 Relevant electrical parts \u2022 Fusing unit&nbsp;\u2022 IH coil unit (IHC)&nbsp;\u2022 IH magnetic erasing board (IHMEB)&nbsp;\u2022 Printer control board (PRCB) &nbsp; &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c3b03-bizhub-554e-454e\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C3B03 (bizhub 554e\/454e)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[923],"epkb_post_type_1_tag":[],"class_list":["post-10320","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c3-554e-454e-trouble-code"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/10320","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=10320"}],"version-history":[{"count":3,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/10320\/revisions"}],"predecessor-version":[{"id":11267,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/10320\/revisions\/11267"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=10320"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=10320"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=10320"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}