{"id":10652,"date":"2019-07-09T16:45:36","date_gmt":"2019-07-09T16:45:36","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=10652"},"modified":"2023-12-21T14:38:54","modified_gmt":"2023-12-21T14:38:54","slug":"72-26-bizhub-754e-654e","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=72-26-bizhub-754e-654e","title":{"rendered":"72-26 (bizhub 754e\/654e)"},"content":{"rendered":"\n<p>Contents<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>JAM type<\/td><td>SD exit section<\/td><td><\/td><\/tr><tr><td>JAM code<\/td><td>72-26<\/td><td><\/td><\/tr><tr><td>Detection timing<\/td><td>&lt;When FS-534+SD-511 is installed&gt;&nbsp;<br>The fold exit sensor (PS12) is not turned OFF even after the set period of time has elapsed after it is turned ON by the paper.<\/td><td><\/td><\/tr><tr><td><\/td><td>&lt;When FS-535+SD-512 is installed&gt;<br>The SD exit sensor (PS12) is not turned OFF even after the set period of time has elapsed after it is turned ON by the paper.<\/td><\/tr><tr><td>Misfeed processing location<\/td><td>\u2022 Front door&nbsp;<br>\u2022 Stacker unit<\/td><td><\/td><\/tr><tr><td>Relevant parts<\/td><td>&lt;When FS-534+SD-511 is installed&gt;&nbsp;<br>\u2022 Fold exit sensor (PS12)&nbsp;<br>\u2022 SD drive board (SDDB)&nbsp;<br>\u2022 FS control board (FSCB)<\/td><td><\/td><\/tr><tr><td><\/td><td>&lt;When FS-535+SD-512 is installed&gt;<br>\u2022 Paper transport belt motor (M34)&nbsp;<br>\u2022 SD exit sensor (PS12)&nbsp;<br>\u2022 SD drive board (SDDB)&nbsp;<br>\u2022 FS control board (FSCB) <\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>&nbsp;(2)ProcedureWhen FS-534+SD-511 is installed<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical component<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001104631\/D0001104631.html\">Initial check items<\/a><\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>2<\/td><td>PS12 I\/O check, sensor check<\/td><td>SDDB J9-2 (ON)<\/td><td>SD-511 5-G<\/td><\/tr><tr><td>3<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001103791\/D0001103791.html\">Replace SDDB<\/a>&nbsp;(Part# A3ERPP6J03)<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>4<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001103772\/D0001103772.html\">Replace FSCB<\/a>&nbsp;(Part# A3EPPPBE01)<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001105094\/D0001105094.html\">N.2.5 Saddle stitcher SD-511<\/a>)<\/li><\/ul>\n\n\n\n<p>When FS-535+SD-512 is installed<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical component<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001104631\/D0001104631.html\">Initial check items<\/a><\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>2<\/td><td>PS12 I\/O check, sensor check<\/td><td>SDDB J9-2 (ON)<\/td><td>SD-512 4-G<\/td><\/tr><tr><td>3<\/td><td>M34 operation check<\/td><td>SDDB CN1-1 to 11<\/td><td>SD-512 17-D<\/td><\/tr><tr><td>4<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001103744\/D0001103744.html\">Replace SDDB<\/a>&nbsp;(Part# A3ERPP6J03)<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>5<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001103713\/D0001103713.html\">Replace FSCB<\/a>&nbsp;(Part# A2Y1H10002)<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001105098\/D0001105098.html\">N.2.9 Saddle sticher SD-512<\/a>)<\/li><\/ul>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001104662\/D0001104662.html\">K.1.10.13<\/a>&nbsp;(Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents JAM type SD exit section JAM code 72-26 Detection timing &lt;When FS-534+SD-511 is installed&gt;&nbsp;The fold exit sensor (PS12) is not turned OFF even after the set period of time has elapsed after it is turned ON by the paper. &lt;When FS-535+SD-512 is installed&gt;The SD exit sensor (PS12) is not turned OFF even after the &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=72-26-bizhub-754e-654e\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;72-26 (bizhub 754e\/654e)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[843],"epkb_post_type_1_tag":[],"class_list":["post-10652","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-72-754e-654e"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/10652","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=10652"}],"version-history":[{"count":2,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/10652\/revisions"}],"predecessor-version":[{"id":10655,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/10652\/revisions\/10655"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=10652"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=10652"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=10652"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}