{"id":10664,"date":"2019-07-09T17:10:34","date_gmt":"2019-07-09T17:10:34","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=10664"},"modified":"2023-12-21T14:38:54","modified_gmt":"2023-12-21T14:38:54","slug":"c6002-bizhub-754e-654e","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c6002-bizhub-754e-654e","title":{"rendered":"C6002 (bizhub 754e\/654e)"},"content":{"rendered":"\n<p>Contents <\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>\nTrouble type<\/td><td>\nDF related configuration error 2<\/td><\/tr><tr><td>\nTrouble code<\/td><td>\nC6002<\/td><\/tr><tr><td>\nRank<\/td><td>\nC<\/td><\/tr><tr><td>\nDetection timing<\/td><td>\nInconsistency in the configuration with the \ninstalled DF is detected on the DF.<\/td><\/tr><tr><td>\nTrouble isolation<\/td><td>\n&#8211;<\/td><\/tr><tr><td>\nRelevant electrical parts<\/td><td> \u2022 DF control board (DFCB)  <br> \u2022 Dual scan image processing board  (DSIPB) <\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>\n&nbsp;\n(2)Procedure\n\n\n\n\n<\/p>\n\n\n\n<table class=\"wp-block-table\"><thead><tr><td>\nStep<\/td><td>\nAction<\/td><td>\nControl signal<\/td><td>\nLocation of electrical \ncomponents<\/td><\/tr><\/thead><tbody><tr><td>\n1<\/td><td>\nCheck the type of the installed DF and replace it if \nit is a wrong one.<\/td><td>\n&#8211;<\/td><td>\n&#8211;<\/td><\/tr><tr><td>\n2<\/td><td>\nCorrect the harness connection between DFCB and \nDSIPB if faulty.<\/td><td>\n&#8211;<\/td><td>\n&#8211;<\/td><\/tr><tr><td>\n3<\/td><td>\nCheck the connectors of the dual scan image \nprocessing board (DSIPB) for proper connection, and correct as necessary. \n(Direction of the point of contact and connection state of the flat cable in \nparticular)<\/td><td>\n&#8211;<\/td><td>\n&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li> Link to the layout drawings for related parts by  each trouble code (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001198122\/D0001198122.html\">S.91.  C6002<\/a>)<\/li><\/ul>\n\n\n\n<p>\n\n\n\nDocument Information\n\n\nID\nD0001104803\nRevise ID\nR000003<\/p>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001104803\/D0001104803.html\">K.3.11.2<\/a> (Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type DF related configuration error 2 Trouble code C6002 Rank C Detection timing Inconsistency in the configuration with the installed DF is detected on the DF. Trouble isolation &#8211; Relevant electrical parts \u2022 DF control board (DFCB) \u2022 Dual scan image processing board (DSIPB) &nbsp; (2)Procedure Step Action Control signal Location of electrical &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c6002-bizhub-754e-654e\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C6002 (bizhub 754e\/654e)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[824],"epkb_post_type_1_tag":[],"class_list":["post-10664","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c6-754e-654e-trouble-code"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/10664","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=10664"}],"version-history":[{"count":2,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/10664\/revisions"}],"predecessor-version":[{"id":11222,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/10664\/revisions\/11222"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=10664"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=10664"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=10664"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}