{"id":10677,"date":"2019-07-09T17:41:31","date_gmt":"2019-07-09T17:41:31","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=10677"},"modified":"2023-12-21T14:38:53","modified_gmt":"2023-12-21T14:38:53","slug":"72-35-bizhub-754e-654e","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=72-35-bizhub-754e-654e","title":{"rendered":"72-35 (bizhub 754e\/654e)"},"content":{"rendered":"\n<p>\n\nContents<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>JAM type<\/td><td>PI section<\/td><\/tr><tr><td>JAM code<\/td><td>72-35<\/td><\/tr><tr><td>Detection timing<\/td><td>\u2022 When a paper is fed from the upper tray, the paper entrance sensor \/Lw (PS206) is not turned ON even after the set period of time has elapsed after the paper entrance sensor \/Up (PS201) is turned ON by the paper. <br>\u2022 When a paper is fed from the lower tray, The paper entrance sensor \/Lw (PS206) is not turned ON even after the set period of time has elapsed after the transfer clutch \/Lw (CL202) is turned ON by the paper. <\/td><td><\/td><\/tr><tr><td>Misfeed processing location<\/td><td>Upper door<\/td><\/tr><tr><td>Relevant parts<\/td><td>\u2022 Transfer clutch \/Lw (CL202) <br>\u2022 Paper entrance sensor \/Up (PS201) <br>\u2022 Paper entrance sensor \/Lw (PS206) <br>\u2022 PI drive board (PIDB) <br>\u2022 FS control board (FSCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>&nbsp;(2)Procedure<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical component<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001104631\/D0001104631.html\">Initial check items<\/a><\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>PS201 I\/O check, sensor check<\/td><td>PIDB CN53&lt;A&gt;-2 (ON)<\/td><td>PI-505 8-C to D<\/td><\/tr><tr><td>3<\/td><td>PS206 I\/O check, sensor check<\/td><td>PIDB CN53&lt;A&gt;-5 (ON)<\/td><td>PI-505 8-C to D<\/td><\/tr><tr><td>4<\/td><td>CL202 operation check<\/td><td>PIDB CN56-1 (ON)<\/td><td>PI-505 7-C to D<\/td><\/tr><tr><td>5<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001103764\/D0001103764.html\">Replace PIDB<\/a> (Part# A10AH01001)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>6<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001103713\/D0001103713.html\">Replace FSCB<\/a> (Part# A2Y1H10002)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001105099\/D0001105099.html\">N.2.10 Post inserter PI-505<\/a>)<\/li><\/ul>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001104664\/D0001104664.html\">K.1.10.15<\/a> (Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents JAM type PI section JAM code 72-35 Detection timing \u2022 When a paper is fed from the upper tray, the paper entrance sensor \/Lw (PS206) is not turned ON even after the set period of time has elapsed after the paper entrance sensor \/Up (PS201) is turned ON by the paper. \u2022 When a &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=72-35-bizhub-754e-654e\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;72-35 (bizhub 754e\/654e)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[843],"epkb_post_type_1_tag":[],"class_list":["post-10677","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-72-754e-654e"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/10677","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=10677"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/10677\/revisions"}],"predecessor-version":[{"id":10695,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/10677\/revisions\/10695"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=10677"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=10677"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=10677"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}