{"id":10775,"date":"2019-07-09T18:49:09","date_gmt":"2019-07-09T18:49:09","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=10775"},"modified":"2023-12-21T14:37:43","modified_gmt":"2023-12-21T14:37:43","slug":"72-60-bizhub-754e-654e","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=72-60-bizhub-754e-654e","title":{"rendered":"72-60 (bizhub 754e\/654e)"},"content":{"rendered":"\n<p>\n\nContents<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>JAM type<\/td><td>ZU section<\/td><\/tr><tr><td>JAM code<\/td><td>72-60<\/td><\/tr><tr><td>Detection timing<\/td><td>The corresponding side edge sensor on the paper size detect board (PSDTB) is not turned ON even after the set period of time has elapsed after the leading, trailing, or side edge sensor on PSDTB is turned OFF by the paper. Or the punch home sensor (PS606) is not turned ON by the paper even after the set period of time has elapsed after the punch clutch (CL601) is turned ON.<\/td><td><\/td><\/tr><tr><td>Misfeed processing location<\/td><td>\u2022 Front door <br>\u2022 Z folding\/conveyance unit<\/td><\/tr><tr><td>Relevant parts<\/td><td>\u2022 Punch clutch (CL601) <br>\u2022 Punch home sensor (PS606) <br>\u2022 Paper size detect board (PSDTB) <br>\u2022 ZU control board (ZUCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>&nbsp;(2)Procedure<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical component<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001104631\/D0001104631.html\">Initial check items<\/a><\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>PS606 I\/O check, sensor check<\/td><td>ZUCB CN3-5 (ON)<\/td><td>ZU-606 7-C<\/td><\/tr><tr><td>3<\/td><td>CL601 operation check<\/td><td>ZUCB CN11-4<\/td><td>ZU-606 7-C<\/td><\/tr><tr><td>4<\/td><td>PSDTB I\/O check, sensor check<\/td><td>ZUCB CN2-1 to 10<\/td><td>ZU-606 9 to 10-C to D<\/td><\/tr><tr><td>5<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001103700\/D0001103700.html\">Replace ZUCB<\/a> (Part# A109H01002)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001105095\/D0001105095.html\">N.2.6 Z folding unit ZU-606<\/a>)<\/li><\/ul>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001104677\/D0001104677.html\">K.1.10.28<\/a> (Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents JAM type ZU section JAM code 72-60 Detection timing The corresponding side edge sensor on the paper size detect board (PSDTB) is not turned ON even after the set period of time has elapsed after the leading, trailing, or side edge sensor on PSDTB is turned OFF by the paper. Or the punch home &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=72-60-bizhub-754e-654e\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;72-60 (bizhub 754e\/654e)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[843],"epkb_post_type_1_tag":[],"class_list":["post-10775","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-72-754e-654e"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/10775","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=10775"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/10775\/revisions"}],"predecessor-version":[{"id":10776,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/10775\/revisions\/10776"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=10775"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=10775"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=10775"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}