{"id":10847,"date":"2019-07-10T14:59:10","date_gmt":"2019-07-10T14:59:10","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=10847"},"modified":"2023-12-21T14:26:09","modified_gmt":"2023-12-21T14:26:09","slug":"c1103-bizhub-754e-654e","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c1103-bizhub-754e-654e","title":{"rendered":"C1103  (bizhub 754e\/654e)"},"content":{"rendered":"\n<p>\n\nContents<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>Alignment plate motor\/F home sensor malfunction<\/td><\/tr><tr><td>Trouble code<\/td><td>C1103<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Detection timing<\/td><td>  &lt;When FS-534 is installed> <br>\u2022 The alignment plate\/F home sensor (PS12) is not unblocked after the set period of time has elapsed after the plate drive starts from the home position. <br>\u2022  The alignment plate\/F home sensor (PS12) is not blocked after the set period of time has elapsed after the alignment motor\/front (M7) is turned ON to return the plate to the home position, <br>\u2022  The alignment plate\/F does not reach the specified position within the set period of time. <\/td><td><\/td><\/tr><tr><td><\/td><td> When FS-535 is installed> <br>The alignment plate motor home sensor\/Fr (PS17) is not blocked even after the set period of time has elapsed while the Alignment plate motor\/Fr (M11) is energized.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>&lt;When FS-534 is installed> <br>\u2022 Alignment motor\/Front (M7) <br>\u2022  Alignment plate\/F home sensor (PS12) <br>\u2022  FS control board (FSCB) <\/td><td><\/td><\/tr><tr><td><\/td><td>  &lt;When FS-535 is installed> <br>\u2022  Alignment plate motor\/Fr (M11) <br>\u2022  Alignment plate motor home sensor\/F (PS17) <br>\u2022  FS control board (FSCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>&nbsp;(2)ProcedureWhen FS-534 is installed<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical components<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td>Check the connector between M7-FSCB J4 for proper connection and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>Check the connector of M7 for proper drive coupling, and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>3<\/td><td>Check the connector between PS12-FSCB J4 for proper connection and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>4<\/td><td>PS12 I\/O check, sensor check<\/td><td>FSCB J4&lt;B&gt;-4 (ON)<\/td><td>FS-534 13-C<\/td><\/tr><tr><td>5<\/td><td>M7 operation check<\/td><td>FSCB J4&lt;A&gt;-5 to 8<\/td><td>FS-534 11-C to D<\/td><\/tr><tr><td>6<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001103779\/D0001103779.html\">Replace M7<\/a> (Part# A3EPPP5500 )<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>7<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001103772\/D0001103772.html\">Replace FSCB<\/a>  (Part# A3EPPPBE01 )<br><\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001105093\/D0001105093.html\">N.2.4 Finisher FS-534<\/a>)<\/li><li>Link to the layout drawings for related parts by each trouble code (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001197983\/D0001197983.html#sct_2\">S.16.1 FS-534<\/a>)<\/li><\/ul>\n\n\n\n<p>When FS-535 is installed<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical components<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td>Check the connector between M11-FSCB CN19 for proper connection and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>Check the connector of M11 for proper drive coupling, and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>3<\/td><td>Check the connector between PS17-FSCB CN20 for proper connection and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>4<\/td><td>PS17 I\/O check, sensor check<\/td><td>FSCB CN20-6 (ON)<\/td><td>FS-535 12-D<\/td><\/tr><tr><td>5<\/td><td>M11 operation check<\/td><td>FSCB CN19-1 to 4<\/td><td>FS-535 10-D<\/td><\/tr><tr><td>6<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001103722\/D0001103722.html\">Replace M11<\/a> (Part# A2Y1R70200 )<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>7<\/td><td>FSCB ICP4 conduction check<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>8<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001103713\/D0001103713.html\">Replace FSCB<\/a> (Part# A2Y1H10002 )<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001105096\/D0001105096.html\">N.2.7 Finisher FS-535<\/a>)<\/li><li>Link to the layout drawings for related parts by each trouble code (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001197983\/D0001197983.html#sct_3\">S.16.2 FS-535<\/a>)<\/li><\/ul>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p>(Link to the Field Service Manual)  <a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001104723\/D0001104723.html\">K.3.6.7<\/a> <\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type Alignment plate motor\/F home sensor malfunction Trouble code C1103 Rank B Detection timing &lt;When FS-534 is installed> \u2022 The alignment plate\/F home sensor (PS12) is not unblocked after the set period of time has elapsed after the plate drive starts from the home position. \u2022 The alignment plate\/F home sensor (PS12) is &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c1103-bizhub-754e-654e\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C1103  (bizhub 754e\/654e)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[819],"epkb_post_type_1_tag":[],"class_list":["post-10847","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c1-754e-654e-trouble-code"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/10847","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=10847"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/10847\/revisions"}],"predecessor-version":[{"id":10848,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/10847\/revisions\/10848"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=10847"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=10847"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=10847"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}