{"id":10856,"date":"2019-07-10T16:42:52","date_gmt":"2019-07-10T16:42:52","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=10856"},"modified":"2023-12-21T14:26:09","modified_gmt":"2023-12-21T14:26:09","slug":"72-81-bizhub-754e-654e","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=72-81-bizhub-754e-654e","title":{"rendered":"72-81 (bizhub 754e\/654e)"},"content":{"rendered":"\n<p>\n\nContents<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>JAM type<\/td><td>FS staple section<\/td><\/tr><tr><td>JAM code<\/td><td>72-81<\/td><\/tr><tr><td>Detection timing<\/td><td>&lt;When FS-535 is installed> <br>The stapler position sensor\/4 (PS53) is not blocked even after the set period of time has elapsed after the stapler motor (M14) operation started.  <\/td><td><\/td><td><\/td><\/tr><tr><td>Misfeed processing location<\/td><td>Front door<\/td><\/tr><tr><td>Relevant parts<\/td><td>&lt;When FS-535 is installed> <br>\u2022 Stapler motor (M14) <br>\u2022 Stapler position sensor\/4 (PS53) <br>\u2022 FS control board (FSCB) <\/td><td><\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>&nbsp;(2)ProcedureWhen FS-535 is installed<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical component<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001104631\/D0001104631.html\">Initial check items<\/a><\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>M14 operation check<\/td><td>FSCB CN15-1 to 2<\/td><td>FS-535 8 to 9-D<\/td><\/tr><tr><td>3<\/td><td>PS53 I\/O check, sensor check<\/td><td>FSCB CN23-12 (ON)<\/td><td>FS-535 12-L<\/td><\/tr><tr><td>4<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001103713\/D0001103713.html\">Replace FSCB<\/a> (Part# A2Y1H10002)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001105096\/D0001105096.html\">N.2.7 Finisher FS-535<\/a>)<\/li><\/ul>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub754eService\/D0001104681\/D0001104681.html\">K.1.10.32<\/a> (Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents JAM type FS staple section JAM code 72-81 Detection timing &lt;When FS-535 is installed> The stapler position sensor\/4 (PS53) is not blocked even after the set period of time has elapsed after the stapler motor (M14) operation started. Misfeed processing location Front door Relevant parts &lt;When FS-535 is installed> \u2022 Stapler motor (M14) \u2022 &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=72-81-bizhub-754e-654e\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;72-81 (bizhub 754e\/654e)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[843],"epkb_post_type_1_tag":[],"class_list":["post-10856","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-72-754e-654e"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/10856","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=10856"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/10856\/revisions"}],"predecessor-version":[{"id":10857,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/10856\/revisions\/10857"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=10856"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=10856"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=10856"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}