{"id":1176,"date":"2019-04-30T12:18:27","date_gmt":"2019-04-30T12:18:27","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=1176"},"modified":"2023-12-27T18:03:51","modified_gmt":"2023-12-27T18:03:51","slug":"14-40-bizhub-c360i-c300i-c250i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=14-40-bizhub-c360i-c300i-c250i","title":{"rendered":"14-40 (bizhub C360i\/C300i\/C250i)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>JAM type<\/td><td><br>Misfeed at tray 4 paper feed section<\/td><\/tr><tr><td>JAM code<\/td><td>14-40<\/td><\/tr><tr><td>JAM detection timing<\/td><td>For paper fed from the tray 4, the image write start signal permit continues to be disabled for a predetermined period of time after the timing of the image write start signal output. <\/td><\/tr><tr><td>&#8211;<\/td><td>Paper jam of a sheet of paper left at the tray 4 paper feed section results, if the tray 4 vertical transport sensor (PS123) is turned ON when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset. <\/td><\/tr><tr><td>&#8211;<\/td><td>Paper jam of a sheet of paper left at the tray 4 paper feed section results, if a sheet of paper is determined to exist at a position detected when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset. <\/td><\/tr><tr><td>Misfeed processing location<\/td><td>\u2022 Right door&nbsp;<br>\u2022 Tray 4<\/td><\/tr><tr><td>Relevant parts<\/td><td>\u2022 Tray 4 paper feed motor (M121)&nbsp;<br>\u2022 Tray 4 vertical transport motor (M122)&nbsp;<br>\u2022 Tray 4 paper feed sensor (PS122)&nbsp;<br>\u2022 Tray 4 vertical transport sensor (PS123)&nbsp;<br>\u2022 PC control board (PCCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><th>Step<\/th><th>Action<\/th><th>Control signal<\/th><th>Location of electrical component<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC360iService\/en-US\/6369798795.html\">Initial check items<\/a><br><\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>2<\/td><td>PS122 I\/O check, sensor check<\/td><td>PCCB CN18C-2 (ON)<\/td><td>PC-216&nbsp;7-K<\/td><\/tr><tr><td>3<\/td><td>PS123 I\/O check, sensor check<\/td><td>PCCB CN18C-5 (ON)<\/td><td>PC-216&nbsp;7-K<\/td><\/tr><tr><td>4<\/td><td>M121 load checkCheck code: 28Multi code: 16, 19, 20<\/td><td>PCCB CN9C-1 to 8<\/td><td>PC-216&nbsp;6-K<\/td><\/tr><tr><td>5<\/td><td>M122 load checkCheck code: 28Multi code: 26, 29, 30<\/td><td>PCCB CN9C-9 to 16<\/td><td>PC-216&nbsp;6-K<\/td><\/tr><tr><td>6<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC360iService\/en-US\/6354111243.html\">Replace PCCB<\/a>. (PC-216 Part# AAV5H00201)<br><\/td><\/tr><\/tbody><\/table>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p> <a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC360iService\/en-US\/6370149387.html\">L.1.5.5<\/a>\u00a0(Link to the Field Service Manual) <\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents JAM type Misfeed at tray 4 paper feed section JAM code 14-40 JAM detection timing For paper fed from the tray 4, the image write start signal permit continues to be disabled for a predetermined period of time after the timing of the image write start signal output. &#8211; Paper jam of a sheet &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=14-40-bizhub-c360i-c300i-c250i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;14-40 (bizhub C360i\/C300i\/C250i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[415],"epkb_post_type_1_tag":[],"class_list":["post-1176","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-10_"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/1176","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1176"}],"version-history":[{"count":4,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/1176\/revisions"}],"predecessor-version":[{"id":8209,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/1176\/revisions\/8209"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1176"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=1176"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=1176"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}