{"id":13027,"date":"2019-07-23T19:43:33","date_gmt":"2019-07-23T19:43:33","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=13027"},"modified":"2023-12-21T13:55:27","modified_gmt":"2023-12-21T13:55:27","slug":"c3725-bizhub-c754e-c654e","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c3725-bizhub-c754e-c654e","title":{"rendered":"C3725 (bizhub C754e\/C654e)"},"content":{"rendered":"\n<p>Contents<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>Fusing abnormally high temperature detection (Center of the heating roller)<\/td><\/tr><tr><td>Trouble code<\/td><td>C3725<\/td><\/tr><tr><td>Rank<\/td><td>A<\/td><\/tr><tr><td>Detection timing<\/td><td>The heating roller temperature sensor continues to detect a temperature higher than a predetermined one for a predetermined period of time.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>\u2022 Fusing unit <br>\u2022 Heating roller temperature sensor (TEMS2) <br>\u2022 IH power supply (IHPU) <br>\u2022 Noise filter (NF1) <br>\u2022 Printer control board (PRCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>&nbsp;(2)Procedure<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical components<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td>Check the fusing unit for correct installation (whether it is secured in position).<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>2<\/td><td>Check the open\/close operation of the upper right door.<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>3<\/td><td>Check the fusing unit, IHPU, NF1 and PRCB for proper connection and correct or change as necessary.<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>4<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC754eService\/D0001044298\/D0001044298.html\">Replace the fusing unit<\/a>&nbsp;(Part# A2X0R71055)<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>5<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC754eService\/D0001044418\/D0001044418.html\">Replace IHPU<\/a>&nbsp;(Part# A61DM40A00)<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>6<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC754eService\/D0001044408\/D0001044408.html\">Replace PRCB<\/a>&nbsp;(Part# A2X0H00S06)<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>7<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC754eService\/D0001044406\/D0001044406.html\">Replace NF1<\/a>&nbsp;(Part# A2XKM40J00)<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the layout drawings for related parts by each trouble code (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC754eService\/D0001108364\/D0001108364.html\">S.72. C3425, C3725, C3825, C3925<\/a>)<\/li><li>Link to the layout drawings for related parts by each trouble code (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC754eService\/D0001108365\/D0001108365.html\">S.73. C3722, C3726, C3822, C3903, C3922, C3926<\/a>)<\/li><\/ul>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC754eService\/D0001045619\/D0001045619.html\">K.3.8.7<\/a>&nbsp;(Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type Fusing abnormally high temperature detection (Center of the heating roller) Trouble code C3725 Rank A Detection timing The heating roller temperature sensor continues to detect a temperature higher than a predetermined one for a predetermined period of time. Trouble isolation &#8211; Relevant electrical parts \u2022 Fusing unit \u2022 Heating roller temperature sensor &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c3725-bizhub-c754e-c654e\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C3725 (bizhub C754e\/C654e)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[872],"epkb_post_type_1_tag":[],"class_list":["post-13027","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c3-c754e-c654e-trouble-code"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/13027","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=13027"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/13027\/revisions"}],"predecessor-version":[{"id":13028,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/13027\/revisions\/13028"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=13027"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=13027"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=13027"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}