{"id":13603,"date":"2019-07-29T16:52:06","date_gmt":"2019-07-29T16:52:06","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=13603"},"modified":"2023-12-18T19:56:13","modified_gmt":"2023-12-18T19:56:13","slug":"99-09-bizhub-c754e-c654e","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=99-09-bizhub-c754e-c654e","title":{"rendered":"99-09 (bizhub C754e\/C654e)"},"content":{"rendered":"\n<p>\n\nContents<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>JAM type<\/td><td>Controller JAM (finisher not completing a job)<\/td><\/tr><tr><td>JAM code<\/td><td>99-09<\/td><\/tr><tr><td>Detection timing<\/td><td>\u2022 A paper exit or paper finishing process inside the finisher is not completed. <br>\u2022 The finisher does not start during a reset procedure from the jam.<\/td><td><\/td><\/tr><tr><td>Misfeed processing location<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant parts<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>&nbsp;(2)Procedure<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical component<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC754eService\/D0001045461\/D0001045461.html\">Initial check items<\/a><\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>Open and close the lower front door of the main body, or open and close the front door of the finisher.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC754eService\/D0001090360\/D0001090360.html\">K.1.11.6<\/a> (Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents JAM type Controller JAM (finisher not completing a job) JAM code 99-09 Detection timing \u2022 A paper exit or paper finishing process inside the finisher is not completed. \u2022 The finisher does not start during a reset procedure from the jam. Misfeed processing location &#8211; Relevant parts &#8211; &nbsp;(2)Procedure Step Action Control signal Location &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=99-09-bizhub-c754e-c654e\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;99-09 (bizhub C754e\/C654e)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[866],"epkb_post_type_1_tag":[],"class_list":["post-13603","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-92-c754e-c654e"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/13603","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=13603"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/13603\/revisions"}],"predecessor-version":[{"id":13604,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/13603\/revisions\/13604"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=13603"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=13603"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=13603"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}