{"id":14039,"date":"2019-08-02T13:52:41","date_gmt":"2019-08-02T13:52:41","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=14039"},"modified":"2023-12-18T19:46:51","modified_gmt":"2023-12-18T19:46:51","slug":"cd252-bizhub-c364e-c284e-c224e","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=cd252-bizhub-c364e-c284e-c224e","title":{"rendered":"CD252 (bizhub C364e\/C284e\/C224e)"},"content":{"rendered":"\n<p>\n\nContents<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>No relay circuit boards for IC-414 mounting at IC-414 mount setting<\/td><\/tr><tr><td>Trouble code<\/td><td>CD252<\/td><\/tr><tr><td>Rank<\/td><td>C<\/td><\/tr><tr><td>Detection timing<\/td><td>EFI relay circuit boards (VI-506) are not mounted when the IC-414 is set to mount setting at Service Mode.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>\u2022 MFP board (MFPB) <br>\u2022 EFI relay board (VI-506)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>&nbsp;(2)Procedure<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical components<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td>If the IC-414 is not mounted, access [Service Mode] -> [System 2] ->\u00a0<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC364eService\/D0000993927\/D0000993927.html\">[Image Controller Setting]<\/a>\u00a0and check to see if Controller 0 is set for [Image Controller Setting].<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>Check the EFI relay board (VI-506) connector for proper connection and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>3<\/td><td>Replace EFI relay board (VI-506) (Part# A161H02801)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>4<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC364eService\/D0000992481\/D0000992481.html\">Replace MFPB.<\/a> (Part# A5C1H0200B)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the layout drawings for related parts by each trouble code (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC364eService\/D0001050503\/D0001050503.html\">S.74. C5372, C6901, C6902, C6903, CA051, CA052, CA053, CC170 &#8211; CC186, CC191 &#8211; CC214, CC216, CD211, CD212, CD241, CD242, CD252 &#8211; CD271, CD401 &#8211; CD413, CE001, CE003 &#8211; CE305, CEEE1<\/a>)<\/li><\/ul>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p> <a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC364eService\/D0000994813\/D0000994813.html\">K.3.16.13<\/a> (Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type No relay circuit boards for IC-414 mounting at IC-414 mount setting Trouble code CD252 Rank C Detection timing EFI relay circuit boards (VI-506) are not mounted when the IC-414 is set to mount setting at Service Mode. Trouble isolation &#8211; Relevant electrical parts \u2022 MFP board (MFPB) \u2022 EFI relay board (VI-506) &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=cd252-bizhub-c364e-c284e-c224e\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;CD252 (bizhub C364e\/C284e\/C224e)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[896],"epkb_post_type_1_tag":[],"class_list":["post-14039","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-cd-c364e-c284e-c224e-trouble-code"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/14039","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=14039"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/14039\/revisions"}],"predecessor-version":[{"id":14040,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/14039\/revisions\/14040"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=14039"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=14039"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=14039"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}