{"id":14540,"date":"2019-09-23T13:09:05","date_gmt":"2019-09-23T13:09:05","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=14540"},"modified":"2023-12-18T19:41:09","modified_gmt":"2023-12-18T19:41:09","slug":"c2650-bizhub-c3320i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c2650-bizhub-c3320i","title":{"rendered":"C2650 (bizhub C3320i)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C2650: Main backup media access error<\/td><\/tr><tr><td>Rank<\/td><td>C<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>-The error was found when reading out the data.<br>-The re-written data, which has been read out, checked and founded as error, is read out again and found as error.<br>-The error was found when reading out the counter value.<br>-The main body detects that the backup board is not mounted.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>-Backup board (ERB)<br>-CPU board (CPUB)<br>-Base board (BASEB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between ERB CN1-BASEB CN20E for proper connection and correct as necessary.<\/li><li>Check CPUB for proper installation and correct as necessary.<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC3320iService\/en-US\/7408636555.html\">Replace CPUB.<\/a> (Part# AAJRH01005)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC3320iService\/en-US\/7408577675.html\">Replace BASEB.<\/a> (Part# A93EH02007)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC3320iService\/en-US\/7408590987.html\">Replace ERB.<\/a> (Part# AA2JH00C00)<\/li><li>1. Replace the current ERB with a new one.<\/li><li>2. Replace the following components with new ones. <\/li><li>When the transfer belt unit, transfer roller and the fusing unit have been replaced with new ones, perform [Service Mode] -> [Counter] -> [Life] -> [New Release].<ul><li>Imaging unit (C Part# AAJV0HE, M Part# AAJV0CE, Y Part# AAJV06E, K Part# AAJV01E)<\/li><li>Transfer belt unit (Part# AAJRR70100)<\/li><li>Fusing unit (Part# AAJRR70300)<\/li><li>Transfer roller (Part# AAJRR70500)<\/li><li>Feed roller (Part# A64J564101\/Part# A64J564201), pick-up roller (Part# A64J564201), separation roller (including options) (Part# A00J563600)<\/li><li>Separation pad (Part# AAJRR72200)<\/li><li>Toner filter (Part# A92E158100)<\/li><\/ul><\/li><li>3. Turn ON the main power switch and check to see that warm-up is started.<\/li><li>Make sure that trouble codes other than C2650 or improper IU\/TC placement is not detected.<\/li><li>4. Make the specified readjustments.<\/li><li>If the above actions do not solve the problem, contact KM.<\/li><\/ol>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC3320iService\/en-US\/7398115083.html\">L.3.7.9<\/a> (Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. Contents Trouble type C2650: Main backup media access error Rank C Trouble detection condition -The error was found when reading out the data.-The re-written data, which has been read out, checked and founded as &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c2650-bizhub-c3320i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C2650 (bizhub C3320i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1060],"epkb_post_type_1_tag":[],"class_list":["post-14540","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c2-c3320i-trouble"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/14540","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=14540"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/14540\/revisions"}],"predecessor-version":[{"id":14541,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/14540\/revisions\/14541"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=14540"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=14540"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=14540"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}