{"id":15312,"date":"2019-10-03T16:41:08","date_gmt":"2019-10-03T16:41:08","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=15312"},"modified":"2023-12-18T19:11:06","modified_gmt":"2023-12-18T19:11:06","slug":"c6103-bizhub-c754-c654","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c6103-bizhub-c754-c654","title":{"rendered":"C6103 (bizhub C754\/C654)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><br><\/p>\n\n\n\n<p>Contents<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>Slider over running<\/td><\/tr><tr><td>Trouble code<\/td><td>C6103<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Detection timing<\/td><td>The scanner home sensor detects the scanner at its home position during a period of time that begins with the time when a pre-scan command and a scan preparation command are executed and ends when a home return command is executed.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>Scanner<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>-Scanner home sensor (PS201)<br>-Scanner motor (M201)<br>-Scanner drive board (SCDB)<br>-MFP board (MFPB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>(2)Procedure<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical components<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td>Correct or change the scanner drive (pulley, gear, belt) if it is faulty.<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>2<\/td><td>Correct the scanner motor set screw if loose.<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>3<\/td><td>Adjust [Image Position Leading Edge] and [Feed Direction Adjustment].<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>4<\/td><td>Check the PS201, M201, SCDB and MFPB connector for proper connection and correct as necessary.<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>5<\/td><td>PS201 I\/O check, sensor check<\/td><td>SCDB PJ6-3 (ON)<\/td><td>17-V<\/td><\/tr><tr><td>6<\/td><td>M201 operation check<\/td><td>SCDB PJ4-1 to 7<\/td><td>17-V<\/td><\/tr><tr><td>7<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC654C754Service\/D0000573199\/D0000573199.html\">Replace SCDB<\/a>&nbsp;(Part# A2X0H01A01Old or Part# A2X0H01A12)<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>8<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC654C754Service\/D0000573210\/D0000573210.html\">Replace MFPB<\/a>&nbsp;(Part# A2XKH02004)<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC654C754Service\/D0000574578\/D0000574578.html\">N.1. bizhub C754\/C654<\/a>)<\/li><li>Link to the layout drawings for related parts by each trouble code (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC654C754Service\/D0000842566\/D0000842566.html\">S.92. C6102, C6103<\/a>)<\/li><\/ul>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC654C754Service\/D0000574321\/D0000574321.html\">K.3.11.3<\/a>&nbsp;(Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. Contents Trouble type Slider over running Trouble code C6103 Rank B Detection timing The scanner home sensor detects the scanner at its home position during a period of time that begins with the time &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c6103-bizhub-c754-c654\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C6103 (bizhub C754\/C654)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1107],"epkb_post_type_1_tag":[],"class_list":["post-15312","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c6-c754-c654-trouble"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/15312","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=15312"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/15312\/revisions"}],"predecessor-version":[{"id":15313,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/15312\/revisions\/15313"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=15312"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=15312"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=15312"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}