{"id":15725,"date":"2019-10-10T13:48:14","date_gmt":"2019-10-10T13:48:14","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=15725"},"modified":"2023-12-18T18:56:41","modified_gmt":"2023-12-18T18:56:41","slug":"72-35-bizhub-c754-c654","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=72-35-bizhub-c754-c654","title":{"rendered":"72-35 (bizhub C754\/C654)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p>\n\nContents<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>JAM type<\/td><td>PI section<\/td><\/tr><tr><td>JAM code<\/td><td>72-35<\/td><\/tr><tr><td>Detection timing<\/td><td> -When a paper is fed from the upper tray, the paper entrance sensor \/Lw (PS206) is not turned ON even after the set period of time has elapsed after the paper entrance sensor \/Up (PS201) is turned ON by the paper.<br>-When a paper is fed from the lower tray, The paper entrance sensor \/Lw (PS206) is not turned ON even after the set period of time has elapsed after the transfer clutch \/Lw (CL202) is turned ON by the paper. <\/td><td><\/td><\/tr><tr><td>Misfeed processing location<\/td><td>Upper door<\/td><\/tr><tr><td>Relevant parts<\/td><td>-Transfer clutch \/Lw (CL202)<br>-Paper entrance sensor \/Up (PS201)<br>-Paper entrance sensor \/Lw (PS206)<br>-PI drive board (PIDB)<br>-FS control board (FSCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>(2)Procedure<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical component<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC654C754Service\/D0000574123\/D0000574123.html\">Initial check items<\/a><\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>PS201 I\/O check, sensor check<\/td><td>PIDB CN53&lt;A&gt;-2 (ON)<\/td><td>PI-505 8-C to D<\/td><\/tr><tr><td>3<\/td><td>PS206 I\/O check, sensor check<\/td><td>PIDB CN53&lt;A&gt;-5 (ON)<\/td><td>PI-505 8-C to D<\/td><\/tr><tr><td>4<\/td><td>CL202 operation check<\/td><td>PIDB CN56-1 (ON)<\/td><td>PI-505 7-C to D<\/td><\/tr><tr><td>5<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC654C754Service\/D0000573416\/D0000573416.html\">Replace PIDB<\/a> (Part# A10AH01001)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>6<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC654C754Service\/D0000573368\/D0000573368.html\">Replace FSCB<\/a> (Part# A2Y1H10002)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC654C754Service\/D0000574590\/D0000574590.html\">N.2.10 Post inserter PI-505<\/a>)<\/li><\/ul>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC654C754Service\/D0000574155\/D0000574155.html\">K.1.10.15<\/a> (Link to the Field Service Manual) <\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. Contents JAM type PI section JAM code 72-35 Detection timing -When a paper is fed from the upper tray, the paper entrance sensor \/Lw (PS206) is not turned ON even after the set period &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=72-35-bizhub-c754-c654\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;72-35 (bizhub C754\/C654)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1103],"epkb_post_type_1_tag":[],"class_list":["post-15725","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-1103"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/15725","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=15725"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/15725\/revisions"}],"predecessor-version":[{"id":15726,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/15725\/revisions\/15726"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=15725"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=15725"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=15725"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}