{"id":15897,"date":"2019-10-14T14:34:09","date_gmt":"2019-10-14T14:34:09","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=15897"},"modified":"2023-12-18T18:55:11","modified_gmt":"2023-12-18T18:55:11","slug":"c1144-bizhub-c554-c454","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c1144-bizhub-c554-c454","title":{"rendered":"C1144 (bizhub C554\/C454)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p>\n\nContents<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>Pre-eject drive motors malfunction &lt;When FS-534 is installed><\/td><\/tr><tr><td><\/td><td>Stacker plate drive motors malfunction <\/td><\/tr><tr><td><\/td><\/tr><tr><td>Trouble code<\/td><td>C1144<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Detection timing<\/td><td>&lt;When FS-534 is installed><br>-The pre-eject home sensor (PS21) is not blocked or unblocked even after the set period of time has elapsed after the pre-eject drive motor (M9) is turned ON.<br>-The pre-eject away sensor (PS22) is not blocked or unblocked even after the set period of time has elapsed after the pre-eject drive motor (M9) is turned ON. <\/td><td><\/td><\/tr><tr><td><\/td><td>&lt;When FS-535 is installed><br>The stacker plate home sensor (PS11) is not blocked or unblocked even after the set period of time has elapsed while the stacker plate drive motor (M17) is energized.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>&lt;When FS-534 is installed><br>-Pre-eject drive motor (M9)<br>-Pre-eject home sensor (PS21)<br>-Pre-eject away sensor (PS22)<br>-FS control board (FSCB)<\/td><td><\/td><\/tr><tr><td><\/td><td>&lt;When FS-535 is installed><br>-Stacker plate drive motor (M17)<br>-Stacker plate home sensor (PS11)<br>-FS control board (FSCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>(2)Procedure When FS-534 is installed<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical components<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td>Check the connector between M9-relay CN7&lt;A&gt;-FSCB J13 for proper connection, and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>Check the connector of M9 for proper drive coupling, and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>3<\/td><td>Check the connector between PS21-relay CN8-relay CN7&lt;B&gt;-FSCB J12 for proper connection, and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>4<\/td><td>Check the connector between PS22-relay CN8-relay CN7&lt;B&gt;-FSCB J12 for proper connection, and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>5<\/td><td>PS21 I\/O check, sensor check<\/td><td>FSCB J12-6 (ON)<\/td><td>FS-534 6-C<\/td><\/tr><tr><td>6<\/td><td>PS22 I\/O check, sensor check<\/td><td>FSCB J12-9 (ON)<\/td><td>FS-534 6-C<\/td><\/tr><tr><td>7<\/td><td>M9 operation check<\/td><td>FSCB J13-3 to 4<\/td><td>FS-534 8-C to D<\/td><\/tr><tr><td>8<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454Service\/D0000843422\/D0000843422.html\">Replace M9<\/a> (Part# A87GPP1500)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>9<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454Service\/D0000843413\/D0000843413.html\">Replace FSCB<\/a> (Part# A3EPPPBE01)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454Service\/D0000845274\/D0000845274.html\">N.3.8 FS-534<\/a>)<\/li><li>Link to the layout drawings for related parts by each trouble code (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454Service\/D0000874385\/D0000874385.html#sct_2\">S.43.1 FS-534<\/a>)<\/li><\/ul>\n\n\n\n<p>When FS-535 is installed<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical components<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td>Check the connector between M17-relay CN233-FSCB CN23 for proper connection, and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>Check the connector of M17 for proper drive coupling, and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>3<\/td><td>Check the connector between PS11-FSCB CN20 for proper connection, and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>4<\/td><td>PS11 I\/O check, sensor check<\/td><td>FSCB CN20-12 (ON)<\/td><td>FS-535 12-D<\/td><\/tr><tr><td>5<\/td><td>M17 operation check<\/td><td>FSCB CN23-19 to 20<\/td><td>FS-535 13-L<\/td><\/tr><tr><td>6<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454Service\/D0000843513\/D0000843513.html\">Replace M17<\/a> (Part# A2Y1R70300)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>7<\/td><td>FSCB ICP9 conduction check<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>8<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454Service\/D0000843500\/D0000843500.html\">Replace FSCB<\/a> (Part# A2Y1H10002)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454Service\/D0000845261\/D0000845261.html\">N.3.10 FS-535<\/a>)<\/li><li>Link to the layout drawings for related parts by each trouble code (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454Service\/D0000874385\/D0000874385.html#sct_3\">S.43.2 FS-535<\/a>)<\/li><\/ul>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454Service\/D0000844923\/D0000844923.html\">K3.6.30<\/a> (Link to the Field Service Manual) <\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. Contents Trouble type Pre-eject drive motors malfunction &lt;When FS-534 is installed> Stacker plate drive motors malfunction Trouble code C1144 Rank B Detection timing &lt;When FS-534 is installed>-The pre-eject home sensor (PS21) is not blocked &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c1144-bizhub-c554-c454\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C1144 (bizhub C554\/C454)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1117],"epkb_post_type_1_tag":[],"class_list":["post-15897","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c1-c554-c454-trouble"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/15897","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=15897"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/15897\/revisions"}],"predecessor-version":[{"id":15898,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/15897\/revisions\/15898"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=15897"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=15897"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=15897"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}