{"id":16093,"date":"2019-10-15T13:38:32","date_gmt":"2019-10-15T13:38:32","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=16093"},"modified":"2023-12-18T16:17:20","modified_gmt":"2023-12-18T16:17:20","slug":"c6751-bizhub-c554-c454","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c6751-bizhub-c554-c454","title":{"rendered":"C6751 (bizhub C554\/C454)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p>Contents<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>CCD clamp\/gain adjustment failure<\/td><\/tr><tr><td>Trouble code<\/td><td>C6751<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Detection timing<\/td><td>The adjustment value is 0 or 255 during a CCD clamp adjustment.The peak value of the output data is 64 or less during a CCD gain adjustment.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>Scanner<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>-LED exposure unit (LU201)<br>-CCD board (CCDB)<br>-MFP board (MFPB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>(2)Procedure<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical components<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td>Check the connector between CCDB PJ3-MFPB PJ01 for proper connection and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>Check for possible extraneous light and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>3<\/td><td>Clean the lens, mirrors, CCD surface, and shading sheet if dirty.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>4<\/td><td>Correct reflective mirror of the scanner if faulty, or change scanner mirror.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>5<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454Service\/D0000843283\/D0000843283.html\">Replace CCDB<\/a> (Part# A161R72100)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>6<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454Service\/D0000843293\/D0000843293.html\">Replace MFPB<\/a> (Part# A2XKH02004)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the layout drawings for related parts by each trouble code (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454Service\/D0000874455\/D0000874455.html\">S.111. C6751<\/a>)<\/li><\/ul>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454Service\/D0000844970\/D0000844970.html\">K3.11.6<\/a> (Link to the Field Service Manual) <\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. Contents Trouble type CCD clamp\/gain adjustment failure Trouble code C6751 Rank B Detection timing The adjustment value is 0 or 255 during a CCD clamp adjustment.The peak value of the output data is 64 &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c6751-bizhub-c554-c454\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C6751 (bizhub C554\/C454)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1122],"epkb_post_type_1_tag":[],"class_list":["post-16093","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c6-c554-c454-trouble"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/16093","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=16093"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/16093\/revisions"}],"predecessor-version":[{"id":16094,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/16093\/revisions\/16094"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=16093"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=16093"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=16093"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}