{"id":16392,"date":"2019-10-16T14:04:41","date_gmt":"2019-10-16T14:04:41","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=16392"},"modified":"2023-12-18T15:09:13","modified_gmt":"2023-12-18T15:09:13","slug":"32-05-bizhub-c554-c454","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=32-05-bizhub-c554-c454","title":{"rendered":"32-05 (bizhub C554\/C454)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p>Contents<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>JAM type<\/td><td>Misfeed at exit section<\/td><\/tr><tr><td>JAM code<\/td><td>32-05<\/td><\/tr><tr><td>Detection timing<\/td><td>The paper exit sensor (PS3) is not unblocked even after the lapse of a given period of time after the paper has blocked PS3.<\/td><td><\/td><\/tr><tr><td>\u2013<\/td><td>The paper exit sensor (PS3) is blocked when the main power switch is unblocked, a door or cover is opened and closed, or a misfeed or malfunction is reset.<\/td><\/tr><tr><td>\u2013<\/td><td>In case paper position is detected as locating properly after main power switch is turned ON, door and cover are opened \/ closed or jam\/trouble reset is done, it is regarded as paper jam at exit section.<\/td><\/tr><tr><td>Misfeed processing location<\/td><td>Right door<\/td><\/tr><tr><td>Relevant parts<\/td><td>-Fusing motor (M3)<br>-Switchback motor (M4)<br>-ADU transport motor (M5)<br>-Paper exit clutch (CL8)<br>-Paper exit sensor (PS3)<br>-ADU paper passage sensor\/1 (PS40)<br>-Front side board (FRB)<br>-Printer control board (PRCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>(2)Procedure<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical component<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454Service\/D0000844839\/D0000844839.html\">Initial check items<\/a><\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>2<\/td><td>PS3 I\/O check, sensor check<\/td><td>PRCB CN21-7 (ON)<\/td><td>15-C<\/td><\/tr><tr><td>3<\/td><td>PS40 I\/O check, sensor check<\/td><td>PRCB CN21-10 (ON)<\/td><td>16-C<\/td><\/tr><tr><td>4<\/td><td>CL8 operation check<\/td><td>PRCB CN13-16 (ON)<\/td><td>bizhub C554 24-Cbizhub C454 22-C<\/td><\/tr><tr><td>5<\/td><td>M3 operation check<\/td><td>PRCB CN2-9 (REM)PRCB CN2-12 (LOCK)<\/td><td>bizhub C554 22-Jbizhub C454 21-J<\/td><\/tr><tr><td>6<\/td><td>M4 operation check<\/td><td>PRCB CN12-4 to 7<\/td><td>28-C<\/td><\/tr><tr><td>7<\/td><td>M5 operation check<\/td><td>PRCB CN21-1 to 4<\/td><td>15-C<\/td><\/tr><tr><td>8<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454Service\/D0000843287\/D0000843287.html\">Replace FRB<\/a>&nbsp;(Part# A161H00501)<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>9<\/td><td>PRCB ICP3, IC28 conduction check<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>10<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454Service\/D0000843290\/D0000843290.html\">Replace PRCB<\/a>&nbsp;(C554 Part# A2XKH00104 \/ C454 Part# A4FJH00104)<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454Service\/D0000845267\/D0000845267.html\">N.1. bizhub C554\/C454<\/a>)<\/li><\/ul>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454Service\/D0000844851\/D0000844851.html\">K1.8.2<\/a>&nbsp;(Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. Contents JAM type Misfeed at exit section JAM code 32-05 Detection timing The paper exit sensor (PS3) is not unblocked even after the lapse of a given period of time after the paper has &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=32-05-bizhub-c554-c454\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;32-05 (bizhub C554\/C454)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1131],"epkb_post_type_1_tag":[],"class_list":["post-16392","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-3-c554-c454-jam"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/16392","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=16392"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/16392\/revisions"}],"predecessor-version":[{"id":16393,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/16392\/revisions\/16393"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=16392"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=16392"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=16392"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}