{"id":16555,"date":"2019-10-17T14:14:11","date_gmt":"2019-10-17T14:14:11","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=16555"},"modified":"2023-12-18T15:05:57","modified_gmt":"2023-12-18T15:05:57","slug":"c1103-bizhub-c364-c284-c224","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c1103-bizhub-c364-c284-c224","title":{"rendered":"C1103 (bizhub C364\/C284\/C224)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p>\n\nContents<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>Alignment plate motor\/Frs malfunction<\/td><\/tr><tr><td>Trouble code<\/td><td>C1103<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Detection timing<\/td><td>&lt;When FS-533 is installed><br>-The alignment plate home sensor\/F (PS108) is not unblocked after the set period of time has elapsed after the plate drive starts from the home position.<br>-The alignment plate home sensor\/F (PS108) is not blocked after the set period of time has elapsed after the alignment motor\/F (M105) is turned ON to return the plate to the home position.<\/td><td><\/td><\/tr><tr><td><\/td><td>&lt;When FS-534 is installed><br>-The alignment plate\/F home sensor (PS12) is not unblocked after the set period of time has elapsed after the plate drive starts from the home position.<br>-The alignment plate\/F home sensor (PS12) is not blocked after the set period of time has elapsed after the alignment motor\/front (M7) is turned ON to return the plate to the home position.<br>-The alignment plate\/F does not reach the specified position within the set period of time.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>&lt;When FS-533 is installed><br>-Alignment motor\/F (M105)<br>-Alignment plate home sensor\/F (PS108)<br>-FS control board (FSCB)<\/td><td><\/td><\/tr><tr><td><\/td><td>&lt;When FS-534 is installed><br>-Alignment motor\/Front (M7)<br>-Alignment plate\/F home sensor (PS12)<br>-FS control board (FSCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>(2)Procedure When FS-533 is installed<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical components<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td>Check the connector between M105-FSCB CN102 for proper connection and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>Check the connector of M105 for proper drive coupling and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>3<\/td><td>Check the connector between PS108-FSCB CN102 for proper connection and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>4<\/td><td>PS108 I\/O check, sensor check<\/td><td>FSCB CN102<\/td><td>FS-533 7-J<\/td><\/tr><tr><td>5<\/td><td>M105 operation check<\/td><td>FSCB CN102<\/td><td>FS-533 7-J<\/td><\/tr><tr><td>6<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC224Service\/D0000827048\/D0000827048.html\">Replace M105<\/a> (Part# A2YUPPW600)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>7<\/td><td>FSCB CP105 conduction check<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>8<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC224Service\/D0000827042\/D0000827042.html\">Replace FSCB<\/a> (Part# A2YUPPH901(Model No. A2YU-WY1) or A2YUPPXN00 (Model No. A2YU-WY2))<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC224Service\/D0000584323\/D0000584323.html\">N.2.6 FS-533<\/a>)<\/li><li>Link to the layout drawings for related parts by each trouble code (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC224Service\/D0000846002\/D0000846002.html#sct_1\">S.16.1 FS-533<\/a>)<\/li><\/ul>\n\n\n\n<p>When FS-534 is installed<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical components<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td>Check the connector between M7-FSCB J4 for proper connection and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>Check the connector of M7 for proper drive coupling, and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>3<\/td><td>Check the connector between PS12-FSCB J4 for proper connection and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>4<\/td><td>PS12 I\/O check, sensor check<\/td><td>FSCB J4&lt;B&gt;-4 (ON)<\/td><td>FS-534 13-C<\/td><\/tr><tr><td>5<\/td><td>M7 operation check<\/td><td>FSCB J4&lt;A&gt;-5 to 8<\/td><td>FS-534 11-C to D<\/td><\/tr><tr><td>6<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC224Service\/D0000795747\/D0000795747.html\">Replace M7<\/a> (Part# A3EPPP5500)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>7<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC224Service\/D0000795740\/D0000795740.html\">Replace FSCB<\/a> (Part# A3EPPPBE01)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC224Service\/D0000778981\/D0000778981.html\">N.2.7 FS-534<\/a>)<\/li><li>Link to the layout drawings for related parts by each trouble code (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC224Service\/D0000846002\/D0000846002.html#sct_2\">S.16.2 FS-534<\/a>)<\/li><\/ul>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC224Service\/D0000784282\/D0000784282.html\">K3.6.4<\/a> (Link to the Field Service Manual) <\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. Contents Trouble type Alignment plate motor\/Frs malfunction Trouble code C1103 Rank B Detection timing &lt;When FS-533 is installed>-The alignment plate home sensor\/F (PS108) is not unblocked after the set period of time has elapsed &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c1103-bizhub-c364-c284-c224\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C1103 (bizhub C364\/C284\/C224)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1138],"epkb_post_type_1_tag":[],"class_list":["post-16555","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c1-c364-c284-c224-trouble"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/16555","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=16555"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/16555\/revisions"}],"predecessor-version":[{"id":16556,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/16555\/revisions\/16556"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=16555"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=16555"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=16555"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}