{"id":16770,"date":"2019-10-18T12:53:10","date_gmt":"2019-10-18T12:53:10","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=16770"},"modified":"2023-12-18T15:01:38","modified_gmt":"2023-12-18T15:01:38","slug":"c8101-bizhub-c364-c284-c224","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c8101-bizhub-c364-c284-c224","title":{"rendered":"C8101 (bizhub C364\/C284\/C224)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p>\n\nContents<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>Before reading pressure welding alienation mechanism trouble<\/td><\/tr><tr><td>Trouble code<\/td><td>C8101<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Detection timing<\/td><td>&lt;When DF-624 is installed><br>-During a pressure motion being performed, the document reading sensor (PS4) output does not change from H to L.<br>-During a retraction motion being performed, the document reading sensor (PS4) output does not change from L to H.<\/td><td><\/td><\/tr><tr><td><\/td><td>&lt;When DF-701 is installed><br>-During a pressure motion being performed, the document reading sensor (PS6) output does not change from H to L.<br>-During a retraction motion being performed, the document reading sensor (PS6) output does not change from L to H.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>&lt;When DF-624 is installed><br>-Reading roll release motor (M5)<br>-Document reading sensor (PS4)<br>-DF control board (DFCB)<\/td><td><\/td><\/tr><tr><td><\/td><td>&lt;When DF-701 is installed><br>-Reading roller release motor (M4)<br>-Document reading sensor (PS6)<br>-DF control board (DFCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>(2)Procedure When DF-624 is installed<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical components<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td>Check the connector between M5-DFCB J18 for proper connection and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>Check the connector of M5 for proper drive coupling, and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>3<\/td><td>Check the connector between PS4-DFCB J10 for proper connection and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>4<\/td><td>PS4 I\/O check, sensor check<\/td><td>DFCB J10-3 (ON)<\/td><td>DF-624 2-G<\/td><\/tr><tr><td>5<\/td><td>M5 operation check<\/td><td>DFCB J18-4 to 5<\/td><td>DF-624 2-G<\/td><\/tr><tr><td>6<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC224Service\/D0000826177\/D0000826177.html\">Replace M5<\/a> (Part# A3CFPP6J00)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>7<\/td><td>FSCB F8 conduction check<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>8<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC224Service\/D0000826171\/D0000826171.html\">Replace DFCB<\/a> (Part# A3CFPP5Q00)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC224Service\/D0000778980\/D0000778980.html\">N.2.2 DF-624<\/a>)<\/li><li>Link to the layout drawings for related parts by each trouble code (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC224Service\/D0000846073\/D0000846073.html#sct_1\">S.87.1 DF-624<\/a>)<\/li><\/ul>\n\n\n\n<p>When DF-701 is installed<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical components<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td>Check the connector between M4-DFCB J18 for proper connection and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>Check the connector of M4 for proper drive coupling, and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>3<\/td><td>Check the connector between PS6-DFCB J10 for proper connection and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>4<\/td><td>PS6 I\/O check, sensor check<\/td><td>DFCB J10-3 (ON)<\/td><td>DF-701 2-G<\/td><\/tr><tr><td>5<\/td><td>M4 operation check<\/td><td>DFCB J18-4 to 5<\/td><td>DF-701 1-G<\/td><\/tr><tr><td>6<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC224Service\/D0000826041\/D0000826041.html\">Replace M4<\/a> (Part# A3CEPP5700)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>7<\/td><td>FSCB F8 conduction check<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>8<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC224Service\/D0000826034\/D0000826034.html\">Replace DFCB<\/a> (Part# A3CEPP4900)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC224Service\/D0000584314\/D0000584314.html\">N.2.1 DF-701<\/a>)<\/li><li>Link to the layout drawings for related parts by each trouble code (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC224Service\/D0000846073\/D0000846073.html#sct_2\">S.87.2 DF-701<\/a>)<\/li><\/ul>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC224Service\/D0000583820\/D0000583820.html\">K3.12.1<\/a> (Link to the Field Service Manual) <\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. Contents Trouble type Before reading pressure welding alienation mechanism trouble Trouble code C8101 Rank B Detection timing &lt;When DF-624 is installed>-During a pressure motion being performed, the document reading sensor (PS4) output does not &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c8101-bizhub-c364-c284-c224\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C8101 (bizhub C364\/C284\/C224)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1144],"epkb_post_type_1_tag":[],"class_list":["post-16770","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c8-c364-c284-c224-trouble"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/16770","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=16770"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/16770\/revisions"}],"predecessor-version":[{"id":16771,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/16770\/revisions\/16771"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=16770"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=16770"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=16770"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}