{"id":17048,"date":"2019-10-21T13:51:34","date_gmt":"2019-10-21T13:51:34","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=17048"},"modified":"2023-12-18T14:59:13","modified_gmt":"2023-12-18T14:59:13","slug":"66-33-bizhub-c364-c284-c224","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=66-33-bizhub-c364-c284-c224","title":{"rendered":"66-33 (bizhub C364\/C284\/C224)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p>Contents<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>JAM type<\/td><td>DF transport section<\/td><\/tr><tr><td>JAM code<\/td><td>66-33<\/td><\/tr><tr><td>Detection timing<\/td><td>&lt;When DF-624 is installed><br>The document reading sensor (PS4) is not blocked after a lapse of a given time after the document registration sensor (PS3) is unblocked.<\/td><td><\/td><td><\/td><\/tr><tr><td><\/td><td>&lt;When DF-701 is installed><br>The document reading sensor (PS6) is not blocked after a lapse of a given time after the registration sensor (PS3) is unblocked.<\/td><\/tr><tr><td>Misfeed processing location<\/td><td>Left cover<\/td><\/tr><tr><td>Relevant parts<\/td><td>&lt;When DF-624 is installed&gt;<br>-Document reading motor (M1)<br>-Document feed motor (M2)<br>-Registration motor (M3)<br>-After separate sensor (PS2)<br>-Document registration sensor (PS3)<br>-Document reading sensor (PS4)<br>-DF control board (DFCB)<\/td><td><\/td><\/tr><tr><td><\/td><td>&lt;When DF-701 is installed&gt;<br>-Document reading motor (M1)<br>-Document feed motor (M2)<br>-Registration motor (M3)<br>-After separate sensor (PS2)<br>-Registration sensor (PS3)<br>-Document reading sensor (PS6)<br>-DF control board (DFCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>(2)Procedure When DF-624 is installed<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical component<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC224Service\/D0000583570\/D0000583570.html\">Initial check items<\/a><\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>2<\/td><td>PS2 I\/O check, sensor check<\/td><td>DFCB J14-8 (ON)<\/td><td>DF-624 6-G<\/td><\/tr><tr><td>3<\/td><td>PS3 I\/O check, sensor check<\/td><td>DFCB J14-12 (ON)<\/td><td>DF-624 5-G<\/td><\/tr><tr><td>4<\/td><td>PS4 I\/O check, sensor check<\/td><td>DFCB J10-3 (ON)<\/td><td>DF-624 2-G<\/td><\/tr><tr><td>5<\/td><td>M1 operation check<\/td><td>DFCB J7-1 to 4<\/td><td>DF-624 2-B<\/td><\/tr><tr><td>6<\/td><td>M2 operation check<\/td><td>DFCB J5-1 to 4<\/td><td>DF-624 2-B<\/td><\/tr><tr><td>7<\/td><td>M3 operation check<\/td><td>DFCB J6-1 to 4<\/td><td>DF-624 3-B<\/td><\/tr><tr><td>8<\/td><td>DFCB F4, F5 conduction check<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>9<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC224Service\/D0000826171\/D0000826171.html\">Replace DFCB<\/a>&nbsp;(Part# A3CFPP5Q00)<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC224Service\/D0000778980\/D0000778980.html\">N.2.2 DF-624<\/a>)<\/li><\/ul>\n\n\n\n<p>When DF-701 is installed<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical component<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC224Service\/D0000583570\/D0000583570.html\">Initial check items<\/a><\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>2<\/td><td>PS2 I\/O check, sensor check<\/td><td>DFCB J14-8 (ON)<\/td><td>DF-701 6-G<\/td><\/tr><tr><td>3<\/td><td>PS3 I\/O check, sensor check<\/td><td>DFCB J14-12 (ON)<\/td><td>DF-701 4-G<\/td><\/tr><tr><td>4<\/td><td>PS6 I\/O check, sensor check<\/td><td>DFCB J10-3 (ON)<\/td><td>DF-701 2-G<\/td><\/tr><tr><td>5<\/td><td>M1 operation check<\/td><td>DFCB J7-1 to 4<\/td><td>DF-701 1-B<\/td><\/tr><tr><td>6<\/td><td>M2 operation check<\/td><td>DFCB J5-1 to 4<\/td><td>DF-701 1 to 2-B<\/td><\/tr><tr><td>7<\/td><td>M3 operation check<\/td><td>DFCB J6-1 to 4<\/td><td>DF-701 2-B<\/td><\/tr><tr><td>8<\/td><td>DFCB F4, F5 conduction check<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>9<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC224Service\/D0000826034\/D0000826034.html\">Replace DFCB<\/a>&nbsp;(Part# A3CEPP4900)<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC224Service\/D0000584314\/D0000584314.html\">N.2.1 DF-701<\/a>)<\/li><\/ul>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC224Service\/D0000583599\/D0000583599.html\">K1.9.3<\/a>&nbsp;(Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. Contents JAM type DF transport section JAM code 66-33 Detection timing &lt;When DF-624 is installed>The document reading sensor (PS4) is not blocked after a lapse of a given time after the document registration sensor &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=66-33-bizhub-c364-c284-c224\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;66-33 (bizhub C364\/C284\/C224)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1153],"epkb_post_type_1_tag":[],"class_list":["post-17048","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-6-c364-c284-c224-jam"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/17048","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=17048"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/17048\/revisions"}],"predecessor-version":[{"id":17049,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/17048\/revisions\/17049"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=17048"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=17048"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=17048"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}