{"id":17367,"date":"2019-10-22T19:38:26","date_gmt":"2019-10-22T19:38:26","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=17367"},"modified":"2023-12-18T14:52:48","modified_gmt":"2023-12-18T14:52:48","slug":"c3425-bizhub-c759-c659","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c3425-bizhub-c759-c659","title":{"rendered":"C3425 (bizhub C759\/C659)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"436F6E74656E7473\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C3425: Fusing warm-up trouble<\/td><\/tr><tr><td>Rank<\/td><td>A<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>-After warm-up operation starts, the heating roller temperature sensor\/1 (TEMS1) does not detect a temperature increasing to a predetermined one though a predetermined period of time has elapsed.<br>-From the start of warm-up operation, it does not terminate within a predetermined period of time.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>-Fusing unit<br>-Heating roller temperature sensor\/1 (TEMS1)<br>-IH power supply unit (IHPU)<br>-Noise filter (NF1)<br>-MFP board (MFPB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"50726F636564757265\">&nbsp;Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the fusing unit for correct installation (whether it is secured in position).<\/li><li>Check the open\/close operation of the upper right door.<\/li><li>Check the connector between TEMS1-relay CN512-MFPB CN31E for proper connection and correct as necessary.<\/li><li>Check the connector between NF1 CN1-CN1AC for proper connection and correct as necessary.<\/li><li>Check the connector between NF1 CN2-IHPU CN1 for proper connection and correct as necessary. (Japan and Taiwan model only)<\/li><li>Check the connector between NF1 CN3-MFPB CN29E for proper connection and correct as necessary.<\/li><li>Check the connector between IHPU CN6-MFPB CN26E for proper connection and correct as necessary.<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC759service\/en-US\/4642054283.html\">Replace the fusing unit.<\/a> (Part# A8JER70222)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC759service\/en-US\/5021784331.html\">Replace IHPU.<\/a> (Part# A8KNM40A02)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC759service\/en-US\/5021671051.html\">Replace NF1.<\/a> (Part# A795M40J00)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC759service\/en-US\/5021710987.html\">Replace MFPB.<\/a> (Part# A8JEH02002)<\/li><\/ol>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC759service\/en-US\/37499133554820977931.html\">L.3.10.8<\/a> (Link to the Field Service Manual) <\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. Contents Trouble type C3425: Fusing warm-up trouble Rank A Trouble detection condition -After warm-up operation starts, the heating roller temperature sensor\/1 (TEMS1) does not detect a temperature increasing to a predetermined one though a &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c3425-bizhub-c759-c659\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C3425 (bizhub C759\/C659)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1161],"epkb_post_type_1_tag":[],"class_list":["post-17367","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c3-c759-c659-trouble"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/17367","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=17367"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/17367\/revisions"}],"predecessor-version":[{"id":17368,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/17367\/revisions\/17368"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=17367"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=17367"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=17367"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}