{"id":17511,"date":"2019-10-23T19:11:45","date_gmt":"2019-10-23T19:11:45","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=17511"},"modified":"2023-12-18T14:51:08","modified_gmt":"2023-12-18T14:51:08","slug":"c9402-bizhub-c759-c659","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c9402-bizhub-c759-c659","title":{"rendered":"C9402 (bizhub C759\/C659)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"436F6E74656E7473\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C9402: Exposure LED lighting abnormally<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>The average output value of the CCD sensor with the scanner at its standby position is a predetermined value or more at the end of a scan job.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>Scanner<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>-LED exposure unit<br>-Flat cable (LED exposure unit)<br>-CCD board (CCDB)<br>-Scanner drive board (SCDB)<br>-MFP board (MFPB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"50726F636564757265\">&nbsp;Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the machine type information registered and reenter as necessary. For details the machine information, see Entering the machine type information.<\/li><li>Correct the harness connection between SCDB CN3-LU201 if faulty.<\/li><li>Correct the harness connection between SCDB CN2-MFPB CN1E if faulty.<\/li><li>Correct the harness connection between CCDB PJ3-MFPB CN9 if faulty.<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC759service\/en-US\/5021417739.html\">Replace the LED exposure unit.<\/a>&nbsp;(Part# A61FM31100)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC759service\/en-US\/5021407755.html\">Replace the CCD unit.<\/a>&nbsp;(Part# A795R71000)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC759service\/en-US\/5021631115.html\">Replace SCDB.<\/a>&nbsp;(Part# A796H01A00)<\/li><li>MFPB F3E conduction check<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC759service\/en-US\/5021710987.html\">Replace MFPB.<\/a>&nbsp;(Part# A8JEH02002)<\/li><\/ol>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC759service\/en-US\/37510452594891143819.html\">L.3.15.1<\/a>&nbsp;(Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. Contents Trouble type C9402: Exposure LED lighting abnormally Rank B Trouble detection condition The average output value of the CCD sensor with the scanner at its standby position is a predetermined value or more &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c9402-bizhub-c759-c659\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C9402 (bizhub C759\/C659)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1166],"epkb_post_type_1_tag":[],"class_list":["post-17511","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c9-c759-c659-trouble"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/17511","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=17511"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/17511\/revisions"}],"predecessor-version":[{"id":17512,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/17511\/revisions\/17512"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=17511"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=17511"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=17511"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}