{"id":17840,"date":"2019-10-25T14:34:48","date_gmt":"2019-10-25T14:34:48","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=17840"},"modified":"2023-12-18T14:43:25","modified_gmt":"2023-12-18T14:43:25","slug":"32-30-bizhub-c759-c659","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=32-30-bizhub-c759-c659","title":{"rendered":"32-30 (bizhub C759\/C659)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"436F6E74656E7473\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>JAM type<\/td><td>Misfeed at fusing\/paper exit section<\/td><\/tr><tr><td>JAM code<\/td><td>32-30<\/td><\/tr><tr><td>JAM detection timing<\/td><td>A trouble of the heating roller assy&#8217;s failure to turn has been detected during a print cycle.<\/td><td><\/td><\/tr><tr><td>\u2013<\/td><td>Paper jam of a sheet of paper left at the exit section results, if the paper exit sensor (PS39) is turned ON (unblocked) when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset.<\/td><\/tr><tr><td>Misfeed processing location<\/td><td>Upper right door<\/td><\/tr><tr><td>Relevant parts<\/td><td>-Exit motor (M4)<br>-Fusing motor (M30)<br>-ADU transport motor\/1 (M31)<br>-Reverse motor (M33)<br>-Gate switch solenoid (SD1)<br>-Paper exit sensor (PS39)<br>-Fusing loop sensor\/Fr (PS41)<br>-Fusing loop sensor\/Rr (PS42)<br>-ADU paper passage sensor\/1 (PS47)<br>-Paper feed\/transport drive board (PFTDB)<br>-MFP board (MFPB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"50726F636564757265\">&nbsp;Procedure<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><th>Step<\/th><th>Action<\/th><th>Control signal<\/th><th>Location of electrical component<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC759service\/en-US\/3746341515.html\">Initial check items<\/a><\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>2<\/td><td>PS39 I\/O check, sensor check<\/td><td>PFTDB CN2-12 (ON)<\/td><td>5-P<\/td><\/tr><tr><td>3<\/td><td>PS41 I\/O check, sensor check<\/td><td>PFTDB CN5-3 (ON)<\/td><td>8-P<\/td><\/tr><tr><td>4<\/td><td>PS42 I\/O check, sensor check<\/td><td>PFTDB CN5-6 (ON)<\/td><td>9-P<\/td><\/tr><tr><td>5<\/td><td>PS47 I\/O check, sensor check<\/td><td>PFTDB CN28-3 (ON)<\/td><td>6-P<\/td><\/tr><tr><td>6<\/td><td>M4 load check<br>-Check code: 27<br>-Multi code: 1, 2, 3, 4<\/td><td>MFPB CN19E-13 to 16<\/td><td>10-K<\/td><\/tr><tr><td>7<\/td><td>M30 load check<br>-Check code: 45<br>-Multi code: 1, 2, 3, 4, 5, 6<\/td><td>MFPB CN28E-1 (DC24V)MFPB CN28E-4 (REM)MFPB CN28E-7 (LOCK)<\/td><td>7-K<\/td><\/tr><tr><td>8<\/td><td>M31 load check<br>-Check code: 85<br>-Multi code: 1, 2, 3, 4<\/td><td>PFTDB CN28-14 to 17<\/td><td>8-P<\/td><\/tr><tr><td>9<\/td><td>M33 load check<br>-Check code: 84<br>-Multi code: 1, 2, 3, 4, 5, 6, 7, 8<\/td><td>MFPB CN19E-9 to 12<\/td><td>10-K<\/td><\/tr><tr><td>10<\/td><td>SD1 load check<br>-Check code: 83<br>-Multi code: 0<\/td><td>MFPB CN19E-7 (DRIVE)<\/td><td>10-K<\/td><\/tr><tr><td>11<\/td><td>PFTDB F10 conduction check<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>12<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC759service\/en-US\/5021651083.html\">Replace PFTDB.<\/a>&nbsp;(Part# A795H00200)<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>13<\/td><td>MFPB F13E or F16E conduction check<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>14<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC759service\/en-US\/5021710987.html\">Replace MFPB.<\/a>&nbsp;(Part# A8JEH02002)<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC759service\/en-US\/37466301554801991435.html\">L.1.8.2<\/a>&nbsp;(Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. Contents JAM type Misfeed at fusing\/paper exit section JAM code 32-30 JAM detection timing A trouble of the heating roller assy&#8217;s failure to turn has been detected during a print cycle. \u2013 Paper jam &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=32-30-bizhub-c759-c659\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;32-30 (bizhub C759\/C659)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1173],"epkb_post_type_1_tag":[],"class_list":["post-17840","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-3-c759-c659-jam"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/17840","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=17840"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/17840\/revisions"}],"predecessor-version":[{"id":17841,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/17840\/revisions\/17841"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=17840"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=17840"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=17840"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}