{"id":17890,"date":"2019-10-25T15:57:11","date_gmt":"2019-10-25T15:57:11","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=17890"},"modified":"2023-12-18T14:42:13","modified_gmt":"2023-12-18T14:42:13","slug":"72-25-bizhub-c759-c659","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=72-25-bizhub-c759-c659","title":{"rendered":"72-25 (bizhub C759\/C659)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"436F6E74656E7473\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>JAM type<\/td><td>Misfeed at SD paper exit section<\/td><\/tr><tr><td>JAM code<\/td><td>72-25<\/td><\/tr><tr><td>JAM detection timing<\/td><td>&lt;When FS-536SD or FS-537SD is installed><br>The fold exit sensor (PS12) is not turned ON by the paper even after the set period of time has elapsed after the half-fold exit operation started.<\/td><td><\/td><td><\/td><\/tr><tr><td>Misfeed processing location<\/td><td>-Front door<br>-Stacker unit<\/td><\/tr><tr><td>Relevant parts<\/td><td>&lt;When FS-536SD or FS-537SD is installed><br>-Fold exit sensor (PS12)<br>-SD control board (SDCB)<br>-FS control board (FSCB)<\/td><td><\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"50726F636564757265\">&nbsp;Procedure<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E2046533533365344206F72204653353337534420697320696E7374616C6C6564\">&nbsp;When FS-536SD or FS-537SD is installed<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><th>Step<\/th><th>Action<\/th><th>Control signal<\/th><th>Location of electrical component<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC759service\/en-US\/3746341515.html\">Initial check items<\/a><\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>PS12 I\/O check, sensor check<\/td><td>SDCB J9-2 (ON)<\/td><td>FS-536\/FS-536SD 5-PFS-537\/FS-537SD 4-P<\/td><\/tr><tr><td>3<\/td><td>Replace SDCB. (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC759service\/en-US\/3738545035.html\">FS-536SD<\/a>\/<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC759service\/en-US\/3738032651.html\">FS-537SD<\/a>) (Part# A3ERPP6J03)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>4<\/td><td>Replace FSCB. (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC759service\/en-US\/3738418571.html\">FS-536SD<\/a> Part# A87GPP0V00 \/<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC759service\/en-US\/3737878027.html\">FS-537SD<\/a> Part# A87HPP9M01)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC759service\/en-US\/37471370354802138635.html\">L.1.10.11<\/a> (Link to the Field Service Manual) <\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. Contents JAM type Misfeed at SD paper exit section JAM code 72-25 JAM detection timing &lt;When FS-536SD or FS-537SD is installed>The fold exit sensor (PS12) is not turned ON by the paper even after &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=72-25-bizhub-c759-c659\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;72-25 (bizhub C759\/C659)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1175],"epkb_post_type_1_tag":[],"class_list":["post-17890","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-7-c759-c659-jam"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/17890","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=17890"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/17890\/revisions"}],"predecessor-version":[{"id":17891,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/17890\/revisions\/17891"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=17890"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=17890"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=17890"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}