{"id":1842,"date":"2019-05-13T18:31:05","date_gmt":"2019-05-13T18:31:05","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=1842"},"modified":"2023-12-27T17:00:16","modified_gmt":"2023-12-27T17:00:16","slug":"c2156-bizhub-c368-c308-c258","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c2156-bizhub-c368-c308-c258","title":{"rendered":"C2156 (bizhub C368\/C308\/C258)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"436F6E74656E7473\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>\u2022 C2156: Transfer belt spacing fault after all pressure established<br><\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>The 1st transfer pressure sensor (PS39) is unblocked after the laps of given time after the 1st transfer pressure clutch (CL5) turned OFF when the pressing operation is finished.<br><\/td><\/tr><tr><td>Trouble isolation<\/td><td>\u2013<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>\u2022 Fusing motor (M3)\u00a0<br>\u2022 1st transfer pressure clutch (CL5)\u00a0<br>\u2022 1st transfer pressure sensor (PS39)\u00a0<br>\u2022 MFP board (MFPB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"50726F636564757265\">&nbsp;Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between M3-MFPB CN8E for proper connection and correct as necessary.<\/li><li>Check the connector of M3 for proper drive coupling and correct as necessary.<\/li><li>Check the connector between PS39-relay CN113-MFPB CN15EB for proper connection and correct as necessary.<\/li><li>Check the connector between CL5-relay CN118-MFPB CN15EA for proper connection and correct as necessary.<\/li><li>PS39 I\/O check, sensor check<ul><li>Control signal: MFPB CN15EB-17 (ON)<\/li><li>Location of electrical component: 10-C<\/li><\/ul><\/li><li>CL5 operation check<ul><li>Control signal: MFPB CN15EA-18 (ON)<\/li><li>Location of electrical component: 8-C<\/li><\/ul><\/li><li>M3 operation check<ul><li>Control signal: MFPB CN8E-9 (REM), MFPB CN8E-12 (LOCK)<\/li><li>Location of electrical component: 2-C<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC368Service\/en-US\/4470854411.html\">Replace M3.<\/a>&nbsp;(Part# A7PUM10000)<\/li><li>MFPB ICP2E conduction check<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC368Service\/en-US\/4470805131.html\">Replace MFPB.<\/a>&nbsp;(Part# A7PUH02123)<\/li><\/ol>\n\n\n\n<p>NOTICE<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC368Service\/en-US\/4491574923.html\">bizhub C368\/C308\/C258<\/a>)<\/li><\/ul>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a rel=\"noreferrer noopener\" href=\"http:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC368Service\/en-US\/4485070219.html\" target=\"_blank\">K.3.11.1<\/a>&nbsp;(Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type \u2022 C2156: Transfer belt spacing fault after all pressure established Rank B Trouble detection condition The 1st transfer pressure sensor (PS39) is unblocked after the laps of given time after the 1st transfer pressure clutch (CL5) turned OFF when the pressing operation is finished. Trouble isolation \u2013 Relevant electrical parts \u2022 Fusing &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c2156-bizhub-c368-c308-c258\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C2156 (bizhub C368\/C308\/C258)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[38],"epkb_post_type_1_tag":[],"class_list":["post-1842","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c2-c368-c308-c258"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/1842","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1842"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/1842\/revisions"}],"predecessor-version":[{"id":1843,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/1842\/revisions\/1843"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1842"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=1842"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=1842"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}