{"id":1855,"date":"2019-05-13T19:00:03","date_gmt":"2019-05-13T19:00:03","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=1855"},"modified":"2023-12-27T17:00:16","modified_gmt":"2023-12-27T17:00:16","slug":"c2355-bizhub-c368-c308-c258","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c2355-bizhub-c368-c308-c258","title":{"rendered":"C2355 (bizhub C368\/C308\/C258)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"436F6E74656E7473\">&nbsp;Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C2355: Transfer belt cleaner cooling fan failure to turn<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>Transfer belt cleaner cooling fan (FM2)MFP board (MFPB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"50726F636564757265\">&nbsp;Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between FM2-relay CN115-relay CN141-MFPB CN15EB for proper connection and correct as necessary.<\/li><li>Check the fan for possible overload and correct as necessary.<\/li><li>FM2 operation check<ul><li>Control signal: MFPB CN15EB-3 (REM), MFPB CN15EB-5 (LOCK)<\/li><li>Location of electrical component: 9-C<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC368Service\/en-US\/4471058571.html\">Replace FM2.<\/a> (Part# 4139M10000)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC368Service\/en-US\/4470805131.html\">Replace MFPB.<\/a> (Part# A7PUH02123)<\/li><\/ol>\n\n\n\n<p>NOTICE<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC368Service\/en-US\/4491574923.html\">bizhub C368\/C308\/C258<\/a>)<\/li><\/ul>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a rel=\"noreferrer noopener\" href=\"http:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC368Service\/en-US\/4485128587.html\" target=\"_blank\">K.3.11.4<\/a> (Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp;Contents Trouble type C2355: Transfer belt cleaner cooling fan failure to turn Rank B Trouble detection condition The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. Trouble isolation &#8211; Relevant electrical parts Transfer belt cleaner cooling fan (FM2)MFP board (MFPB) &nbsp;Procedure Check the connector between FM2-relay &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c2355-bizhub-c368-c308-c258\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C2355 (bizhub C368\/C308\/C258)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[38],"epkb_post_type_1_tag":[],"class_list":["post-1855","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c2-c368-c308-c258"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/1855","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1855"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/1855\/revisions"}],"predecessor-version":[{"id":1857,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/1855\/revisions\/1857"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1855"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=1855"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=1855"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}