{"id":18633,"date":"2019-11-01T14:43:20","date_gmt":"2019-11-01T14:43:20","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=18633"},"modified":"2023-12-18T14:30:48","modified_gmt":"2023-12-18T14:30:48","slug":"c1103-bizhub-287-227","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c1103-bizhub-287-227","title":{"rendered":"C1103 (bizhub 287\/227)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"436F6E74656E7473\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C1103: Alignment plate motor\/Fr malfunction (When FS-533, FS-534 or FS-534SD is installed)<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>&lt;When FS-533 is installed><br>-The alignment plate home sensor\/F (PS108) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position.<br>-The alignment plate home sensor\/F (PS108) is not turned ON (blocked) after the set period of time has elapsed after the alignment motor\/F (M105) is turned ON to return the plate to the home position.<\/td><\/tr><tr><td><\/td><td> &lt;When FS-534 or FS-534SD is installed><br>-The alignment plate\/F home sensor (PS12) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position.<br>-The alignment plate\/F home sensor (PS12) is not turned ON (blocked) after the set period of time has elapsed after the alignment motor\/Front (M7) is turned ON to return the plate to the home position.The alignment plate\/F does not reach the specified position within the set period of time. <\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>&lt;When FS-533 is installed><br>-Alignment motor\/F (M105)<br>-Alignment plate home sensor\/F (PS108)<br>-FS control board (FSCB)<\/td><\/tr><tr><td><\/td><td> &lt;When FS-534 or FS-534SD is installed><br>-Alignment motor\/Front (M7)<br>-Alignment plate\/F home sensor (PS12)<br>-FS control board (FSCB) <\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"50726F636564757265\">&nbsp;Procedure<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E20465335333320697320696E7374616C6C6564\">&nbsp;When FS-533 is installed<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between M105-FSCB CN102 for proper connection and correct as necessary.<\/li><li>Check the connector of M105 for proper drive coupling, and correct as necessary.<\/li><li>Check the connector between PS108-FSCB CN102 for proper connection and correct as necessary.<\/li><li>PS108 I\/O check, sensor check<ul><li>Control signal: FSCB CN102<\/li><li>Location of electrical component: FS-533 7-J<\/li><\/ul><\/li><li>M105 operation check<ul><li>Control signal: FSCB CN102<\/li><li>Location of electrical component: FS-533 7-J<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub287Service\/en-US\/1921140235.html\">Replace M105.<\/a> (Part# A2YUPPW600)<\/li><li>FSCB CP105 conduction check<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub287Service\/en-US\/1921091083.html\">Replace FSCB.<\/a> (Part# A2YUPPH901(Model No. A2YU-WY1) or A2YUPPXN00 (Model No. A2YU-WY2)<\/li><\/ol>\n\n\n\n<p>NOTICE<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub287Service\/en-US\/1944790155.html\">FS-533<\/a>)<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E204653353334206F72204653353334534420697320696E7374616C6C6564\">&nbsp;When FS-534 or FS-534SD is installed<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between M7-FSCB J4 for proper connection and correct as necessary.<\/li><li>Check the connector of M7 for proper drive coupling and correct as necessary.<\/li><li>Check the connector between PS12-FSCB J4 for proper connection and correct as necessary.<\/li><li>PS12 I\/O check, sensor check<ul><li>Control signal: FSCB J4&lt;B>-4 (ON)<\/li><li>Location of electrical component: FS-534 13-C<\/li><\/ul><\/li><li>M7 operation check<ul><li>Control signal: FSCB J4&lt;A>-5 to 8<\/li><li>Location of electrical component: FS-534 11-C to D<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub287Service\/en-US\/1920837771.html\">Replace M7.<\/a> (Part# A3EPPP5500)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub287Service\/en-US\/1920780427.html\">Replace FSCB.<\/a> (Part# A3EPPPBE01)<\/li><\/ol>\n\n\n\n<p>NOTICE<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub287Service\/en-US\/1944795787.html\">FS-534<\/a>)<\/li><\/ul>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub287Service\/en-US\/1939430923.html\">K.3.8.4<\/a> (Link to the Field Service Manual) <\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. Contents Trouble type C1103: Alignment plate motor\/Fr malfunction (When FS-533, FS-534 or FS-534SD is installed) Rank B Trouble detection condition &lt;When FS-533 is installed>-The alignment plate home sensor\/F (PS108) is not turned OFF (unblocked) &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c1103-bizhub-287-227\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C1103 (bizhub 287\/227)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1201],"epkb_post_type_1_tag":[],"class_list":["post-18633","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c1-287-227-trouble"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/18633","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=18633"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/18633\/revisions"}],"predecessor-version":[{"id":18634,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/18633\/revisions\/18634"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=18633"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=18633"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=18633"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}