{"id":19024,"date":"2019-11-05T13:37:11","date_gmt":"2019-11-05T13:37:11","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=19024"},"modified":"2023-12-18T14:27:08","modified_gmt":"2023-12-18T14:27:08","slug":"10-01-bizhub-287-227","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=10-01-bizhub-287-227","title":{"rendered":"10-01 (bizhub 287\/227)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"436F6E74656E7473\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table alignleft is-style-stripes\"><tbody><tr><td>JAM type<\/td><td>Misfeed at manual bypass feed section<\/td><\/tr><tr><td>JAM code<\/td><td>10-01<\/td><\/tr><tr><td>JAM detection timing<\/td><td>The leading edge of the paper is not turned ON (unblocked) the registration sensor (PS1) even after the lapse of a given period of time after the manual bypass tray starts to feed paper.<\/td><td><\/td><\/tr><tr><td>Misfeed processing location<\/td><td>Right door<\/td><\/tr><tr><td>Relevant parts<\/td><td>-Transport motor (M1)<br>-Registration clutch (CL4)<br>-Bypass paper feed clutch (CL7)<br>-Registration sensor (PS1)<br>-MFP board (MFPB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"50726F636564757265\">&nbsp;Procedure<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><th>Step<\/th><th>Action<\/th><th>Control signal<\/th><th>Location of electrical component<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub287Service\/en-US\/1937657867.html\">Initial check items<\/a><\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>PS1 I\/O check, sensor check<\/td><td>MFPB CN14E-3 (ON)<\/td><td>28-C<\/td><\/tr><tr><td>3<\/td><td>CL4 operation check<\/td><td>MFPB CN14E-5 (ON)<\/td><td>28-C<\/td><\/tr><tr><td>4<\/td><td>CL7 operation check<\/td><td>MFPB CN9E-11 (ON)<\/td><td>4-J<\/td><\/tr><tr><td>5<\/td><td>M1 operation check<\/td><td>MFPB CN19E-3 to 7<\/td><td>26-C<\/td><\/tr><tr><td>6<\/td><td>MFPB F5E conduction check<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>7<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub287Service\/en-US\/1919911307.html\">Replace MFPB.<\/a> (Part# A7AHH0201D)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub287Service\/en-US\/1944730507.html\">bizhub 367\/287\/227<\/a>)<\/li><\/ul>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub287Service\/en-US\/1937671947.html\">K.1.6.1<\/a> (Link to the Field Service Manual) <\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. Contents JAM type Misfeed at manual bypass feed section JAM code 10-01 JAM detection timing The leading edge of the paper is not turned ON (unblocked) the registration sensor (PS1) even after the lapse &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=10-01-bizhub-287-227\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;10-01 (bizhub 287\/227)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1213],"epkb_post_type_1_tag":[],"class_list":["post-19024","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-1-287-227-jam"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/19024","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=19024"}],"version-history":[{"count":3,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/19024\/revisions"}],"predecessor-version":[{"id":24464,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/19024\/revisions\/24464"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=19024"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=19024"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=19024"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}