{"id":19219,"date":"2020-02-20T19:46:08","date_gmt":"2020-02-20T19:46:08","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=19219"},"modified":"2023-12-18T14:25:05","modified_gmt":"2023-12-18T14:25:05","slug":"p-14-bizhub-c360i-c300i-c250i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=p-14-bizhub-c360i-c300i-c250i","title":{"rendered":"P-14 (bizhub C360i\/C300i\/C250i)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Malfunction type<\/td><td>Skew correction trouble<\/td><\/tr><tr><td>Malfunction code<\/td><td>P-14<\/td><\/tr><tr><td>Malfunction detection timing<\/td><td>The difference between the skew default position setting value and the cumulative amount of skew adjustment values goes over the predetermined value.<\/td><\/tr><tr><td>Relevant parts<\/td><td>-IDC sensor\/Fr (IDCS\/Fr)<br>-IDC sensor\/Rr (IDCS\/Rr)<br>-Drum unit\/Y,M,C,K<br>-Expansion control board (EXCB)<br>-Base board (BASEB)<br>-PH unit<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the drive transmission portion of the drum unit and correct as necessary.<\/li><li>Clean the contact of the drum unit connector if dirty.<\/li><li>Reinstall or reconnect IDCS\/Fr, connectors connecting between IDCS\/Fr-relay CN77-BASEB CN15E, if any of the foregoing parts is installed or connected improperly.<\/li><li>Reinstall or reconnect IDCS\/Rr, connectors connecting between IDCS\/Rr-relay CN77-BASEB CN15E, if any of the foregoing parts is installed or connected improperly.<\/li><li>Clean IDCS\/Fr or IDCS\/Rr if it is dirty.<\/li><li>Check the connector between the PH unit-relay CN30-EXCB CN7EX for proper connection and correct as necessary.<\/li><li>Check the connectors of the EXCB for proper connection and correct as necessary.<\/li><li>Check the connectors on BASEB for proper connection and correct as necessary.<\/li><li>Replace IDCS\/Fr or IDCS\/Rr. (Part# A161M50300)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC360iService\/en-US\/6351414539.html\">Replace the drum unit.<\/a>  CMY (Part# AAV70TD) \/ K (Part# AAV70RD)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC360iService\/en-US\/6355111947.html\">Replace the PH unit.<\/a> (Part# AA2JR71500)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC360iService\/en-US\/6355340427.html\">Replace EXCB.<\/a> (Part# AA2JH00500)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC360iService\/en-US\/6355451147.html\">Replace BASEB.<\/a> (Part# AA2JH02005)<\/li><\/ol>\n\n\n\n<p><strong>NOTE<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>After the PH unit is replaced, reset the skew default position for each color in [Service Mode] -&gt; [Machine] -&gt; [Print Head Skew Adj.] -&gt; [Print Head Skew Adj.]<\/li><li>When this alert code is displayed, according to the list, take actions to address the problem. After the problem is resolved, select [Service Mode] -&gt; [Machine] -&gt; [Print Head Skew Adj.] -&gt; [Print Head Skew Reset] and perform the skew adjustment reset.<\/li><\/ul>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC360iService\/en-US\/6372559243.html\">L.2.9<\/a> (Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. Contents Malfunction type Skew correction trouble Malfunction code P-14 Malfunction detection timing The difference between the skew default position setting value and the cumulative amount of skew adjustment values goes over the predetermined value. &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=p-14-bizhub-c360i-c300i-c250i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;P-14 (bizhub C360i\/C300i\/C250i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1249],"epkb_post_type_1_tag":[],"class_list":["post-19219","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-p-c360i-c300i-c250i-malfunction"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/19219","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=19219"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/19219\/revisions"}],"predecessor-version":[{"id":19220,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/19219\/revisions\/19220"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=19219"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=19219"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=19219"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}