{"id":19292,"date":"2020-02-24T14:23:15","date_gmt":"2020-02-24T14:23:15","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=19292"},"modified":"2023-12-18T14:19:45","modified_gmt":"2023-12-18T14:19:45","slug":"c1109-bizhub-c650i-c550i-c450i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c1109-bizhub-c650i-c550i-c450i","title":{"rendered":"C1109 (bizhub C650i\/C550i\/C450i)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E20465335333320697320696E7374616C6C6564\">When FS-533 is installed<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C1109: Stapler motor drive malfunction (When&nbsp;FS-533&nbsp;is installed)<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>The stapler home sensor (PS110) is not turned ON (blocked) even after the set period of time has elapsed after the stapler motor is energized.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>Staple<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>-Stapler unit<br>-Stapler home sensor (PS110)<br>-Stapler relay board (STRYB)<br>-FS control board (FSCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between the stapler unit-STRYB CN122, CN123 for proper connection and correct as necessary.<\/li><li>Check the connector of the stapler unit for proper drive coupling and correct as necessary.<\/li><li>Check the connector between PS110-FSCB CN110 for proper connection and correct as necessary.<\/li><li>PS110 I\/O check, sensor check<ul><li>Control signal: FSCB CN110<\/li><li>Location of electrical component:\u00a0FS-533\u00a08-D to E<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC650iService\/en-US\/6222003211.html\">Replace the stapler unit.<\/a> (Part# A2YUPPK401)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC650iService\/en-US\/6222037003.html\">Replace STRYB.<\/a> (Part# A2YUPPG700)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC650iService\/en-US\/6222025227.html\">Replace FSCB.<\/a> (Part# A2YUPPH901(Model No. A2YU-WY1) or A2YUPPXN00 (Model No. A2YU-WY2))<\/li><\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E204653353339206F72204653353339534420697320696E7374616C6C6564\">&nbsp;When FS-539 or FS-539SD is installed<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C1109: Stapler motor drive malfunction (When&nbsp;FS-539&nbsp;or&nbsp;FS-539SD&nbsp;is installed)<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>-The stapler sensor is not turned OFF or ON even after the set period of time has elapsed after the stapler motor is energized.<br>-The stapler center position sensor (PS24) is turned ON (blocked), when the stapler motor is running.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>Staple<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>-Stapler unit<br>-Stapler center position sensor (PS24)<br>-FS control board (FSCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between the stapler unit-relay CN6-FSCB J11 for proper connection and correct as necessary.<\/li><li>Check the connector of the stapler unit for proper drive coupling and correct as necessary.<\/li><li>Check the connector between PS24-relay CN3-FSCB J11 for proper connection and correct as necessary.<\/li><li>PS24 I\/O check, sensor check<ul><li>Control signal: FSCB J11&lt;B>-6 (ON)<\/li><li>Location of electrical component:\u00a0FS-539\/FS-539SD\u00a05-C<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC650iService\/en-US\/6354215563.html\">Replace the stapler unit.<\/a> (Part# A3EP560100)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC650iService\/en-US\/6354222731.html\">Replace FSCB.<\/a> (Part# AAR4PP8201)<\/li><\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E204653353430206F72204653353430534420697320696E7374616C6C6564\">&nbsp;When FS-540 or FS-540SD is installed<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C1109: Stapler motor drive malfunction (When&nbsp;FS-540&nbsp;or&nbsp;FS-540SD&nbsp;is installed)<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>-The stapler sensor is not turned OFF or ON even after the set period of time has elapsed after the stapler motor (M5) is energized.<br>-The stapler center position sensor (PS20) is turned ON (blocked), when the stapler motor (M5) is running.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>Staple<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>-Stapler unit<br>-Stapler center position sensor (PS20)<br>-FS control board (FSCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between the stapler unit-FSCB J17 for proper connection and correct as necessary.<\/li><li>Check the connector of the stapler unit for proper drive coupling and correct as necessary.<\/li><li>Check the connector between PS20-FSCB J16 for proper connection and correct as necessary.<\/li><li>PS20 I\/O check, sensor check<ul><li>Control signal: FSCB J16&lt;A>-3<\/li><li>Location of electrical component:\u00a0FS-540\/FS-540SD\u00a014-K to L<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC650iService\/en-US\/6223481867.html\">Replace the stapler unit.<\/a> (Part# AAR5PPE200)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC650iService\/en-US\/6223494923.html\">Replace FSCB.<\/a> (Part# AAR5PPD401)<\/li><\/ol>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC650iService\/en-US\/8608649099.html\">L.3.8.10<\/a> (Link to the Field Service Manual) <\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. When FS-533 is installed Contents Trouble type C1109: Stapler motor drive malfunction (When&nbsp;FS-533&nbsp;is installed) Rank B Trouble detection condition The stapler home sensor (PS110) is not turned ON (blocked) even after the set period &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c1109-bizhub-c650i-c550i-c450i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C1109 (bizhub C650i\/C550i\/C450i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1229],"epkb_post_type_1_tag":[],"class_list":["post-19292","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c1-c650i-c550i-c450i-trouble"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/19292","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=19292"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/19292\/revisions"}],"predecessor-version":[{"id":19293,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/19292\/revisions\/19293"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=19292"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=19292"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=19292"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}