{"id":20508,"date":"2020-06-23T20:18:55","date_gmt":"2020-06-23T20:18:55","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=20508"},"modified":"2023-12-13T18:42:41","modified_gmt":"2023-12-13T18:42:41","slug":"72-43-bizhub-c750i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=72-43-bizhub-c750i","title":{"rendered":"72-43 (bizhub C750i)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E204653353339504B353234206F722046533533395344504B35323420697320696E7374616C6C6564\">When FS-539+PK-524 or FS-539SD+PK-524 is installed<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>JAM type<\/td><td>Misfeed at PK section (When&nbsp;FS-539+PK-524&nbsp;or&nbsp;FS-539SD+PK-524&nbsp;is installed)<\/td><\/tr><tr><td>JAM code<\/td><td>72-43<\/td><\/tr><tr><td>JAM detection timing<\/td><td>72-43: The punch position sensor (PS2) is not turned ON (unblocked) after a lapse of a given time after the punch drive motor (M1) starts rotating.<\/td><td><\/td><\/tr><tr><td>Misfeed processing location<\/td><td>Front door<\/td><\/tr><tr><td>Relevant parts<\/td><td>-Punch drive motor (M1)<br>-Punch position sensor (PS2)<br>-FS control board (FSCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><th>Step<\/th><th>Action<\/th><th>Control signal<\/th><th>Location of electrical component<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC750iService\/en-US\/6369798795.html\">Initial check items<\/a><\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>PS2 I\/O check, sensor check<\/td><td>FSCB J7-2 (ON)<\/td><td>FS-539\/FS-539SD&nbsp;(PK-524) 13-K<\/td><\/tr><tr><td>3<\/td><td>M1 operation check<\/td><td>FSCB J7-7 to 8<\/td><td>FS-539\/FS-539SD&nbsp;(PK-524) 13-K<\/td><\/tr><tr><td>4<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC750iService\/en-US\/6354222731.html\">Replace FSCB.<\/a> (Part# AAR4PP8201)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E204653353430504B353236206F722046533534305344504B35323620697320696E7374616C6C6564\">&nbsp;When FS-540+PK-526 or FS-540SD+PK-526 is installed<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>JAM type<\/td><td>Misfeed at PK section (When&nbsp;FS-540+PK-526&nbsp;or&nbsp;FS-540SD+PK-526&nbsp;is installed)<\/td><\/tr><tr><td>JAM code<\/td><td>72-43<\/td><\/tr><tr><td>JAM detection timing<\/td><td>72-43: The punch home sensor (PS301) is not turned ON (unblocked) after a lapse of a given time after the punch drive motor (M301) starts rotating.<\/td><td><\/td><\/tr><tr><td><\/td><td>Paper jam of a sheet of paper left at the PK section results, when the main power switch is turned ON, and the paper is detected by the paper size detect board (PSDTB).<\/td><\/tr><tr><td>Misfeed processing location<\/td><td>Front door<\/td><\/tr><tr><td>Relevant parts<\/td><td>72-43:<br>-Punch drive motor (M301)<br>-Punch home sensor (PS301)<br>-Punch control board (PKCB)<br>-FS control board (FSCB)<\/td><td><\/td><\/tr><tr><td>Residual paper jam<\/td><td>-Paper size detect board (PSDTB)<br>-FS control board (FSCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><th>Step<\/th><th>Action<\/th><th>Control signal<\/th><th>Location of electrical component<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC750iService\/en-US\/6369798795.html\">Initial check items<\/a><\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>PS301 I\/O check, sensor check<\/td><td>PKCB CN36-5 (ON)<\/td><td>PK-526&nbsp;3-C<\/td><\/tr><tr><td>3<\/td><td>M301 operation check<\/td><td>PKCB CN35-1 to 3<\/td><td>PK-526&nbsp;2-C<\/td><\/tr><tr><td>4<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC750iService\/en-US\/8613329675.html\">Replace PKCB.<\/a> (Part# A99KH00103)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>5<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC750iService\/en-US\/6223494923.html\">Replace FSCB.<\/a> (Part# AAR5PPD401)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>Residual paper jam<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><th>Step<\/th><th>Action<\/th><th>Control signal<\/th><th>Location of electrical component<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC750iService\/en-US\/6369798795.html\">Initial check items<\/a><\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>Adjust the sensitivity (light intensity) by selecting [Service Mode] -> [Finisher] -> [FS-FN adjustment] -> [Punch F. Sensor Intensity Adj.].<br><br>After adjustment, open and then close the front door, and check if the residual paper jam indication disappears. <br><br>To turn off the main power switch, wait for more than 10 seconds until the residual paper jam indication disappears<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>3<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC750iService\/en-US\/8613329675.html\">Replace PKCB.<\/a> (Part# A99KH00103)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>4<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC750iService\/en-US\/6223494923.html\">Replace FSCB.<\/a> (Part# AAR5PPD401)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC750iService\/en-US\/9175813643.html\">(Link to the Field Service Manual)<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. When FS-539+PK-524 or FS-539SD+PK-524 is installed Contents JAM type Misfeed at PK section (When&nbsp;FS-539+PK-524&nbsp;or&nbsp;FS-539SD+PK-524&nbsp;is installed) JAM code 72-43 JAM detection timing 72-43: The punch position sensor (PS2) is not turned ON (unblocked) after a &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=72-43-bizhub-c750i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;72-43 (bizhub C750i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1273],"epkb_post_type_1_tag":[],"class_list":["post-20508","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-7-c750i-jam"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/20508","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=20508"}],"version-history":[{"count":2,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/20508\/revisions"}],"predecessor-version":[{"id":22477,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/20508\/revisions\/22477"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=20508"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=20508"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=20508"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}