{"id":20528,"date":"2020-06-23T20:37:28","date_gmt":"2020-06-23T20:37:28","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=20528"},"modified":"2023-12-13T18:42:18","modified_gmt":"2023-12-13T18:42:18","slug":"72-77-bizhub-750i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=72-77-bizhub-750i","title":{"rendered":"72-77 (bizhub 750i)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E204653353339206F72204653353339534420697320696E7374616C6C6564\">When FS-539 or FS-539SD is installed<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>JAM type<\/td><td>Misfeed at FS paper exit section (When&nbsp;FS-539&nbsp;or&nbsp;FS-539SD&nbsp;is installed)<\/td><\/tr><tr><td>JAM code<\/td><td>72-77<\/td><\/tr><tr><td>JAM detection timing<\/td><td>72-77: The alignment home sensor (PS12\/PS13) is not turned OFF (unblocked) even after the set period of time has elapsed after the alignment motor (M7\/M8) is energized at the time other than the initial operation.<\/td><td><\/td><\/tr><tr><td>Misfeed processing location<\/td><td>Main tray<\/td><\/tr><tr><td>Relevant parts<\/td><td>-Alignment motor\/Fr (M7)<br>-Alignment motor\/Rr (M8)<br>-Alignment plate home sensor\/Fr (PS12)<br>-Alignment plate home sensor\/Rr (PS13)<br>-FS control board (FSCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><th>Step<\/th><th>Action<\/th><th>Control signal<\/th><th>Location of electrical component<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub750iService\/en-US\/6369798795.html\">Initial check items<\/a><\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>PS12 I\/O check, sensor check<\/td><td>FSCB J4&lt;B&gt;-4 (ON)<\/td><td>FS-539\/FS-539SD&nbsp;14-C<\/td><\/tr><tr><td>3<\/td><td>PS13 I\/O check, sensor check<\/td><td>FSCB J9&lt;B&gt;-12 (ON)<\/td><td>FS-539\/FS-539SD&nbsp;10-C<\/td><\/tr><tr><td>4<\/td><td>M7 operation check<\/td><td>FSCB J4&lt;A&gt;-5 to 8<\/td><td>FS-539\/FS-539SD&nbsp;13 to 14-C<\/td><\/tr><tr><td>5<\/td><td>M8 operation check<\/td><td>FSCB J12-13 to 16<\/td><td>FS-539\/FS-539SD&nbsp;7-C<\/td><\/tr><tr><td>6<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub750iService\/en-US\/6354222731.html\">Replace FSCB.<\/a> (Part# AAR4PP8201)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E204653353430206F72204653353430534420697320696E7374616C6C6564\">&nbsp;When FS-540 or FS-540SD is installed<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>JAM type<\/td><td>Misfeed at FS paper exit section (When&nbsp;FS-540&nbsp;or&nbsp;FS-540SD&nbsp;is installed)<\/td><\/tr><tr><td>JAM code<\/td><td>72-77<\/td><\/tr><tr><td>JAM detection timing<\/td><td>72-77: The alignment home sensor (PS6\/PS9) is not turned OFF (unblocked) even after the set period of time has elapsed after the alignment motor (M13\/M14) is energized at the time other than the initial operation.<\/td><td><\/td><\/tr><tr><td>Misfeed processing location<\/td><td>Main tray<\/td><\/tr><tr><td>Relevant parts<\/td><td>-Alignment motor\/Rr (M13)<br>-Alignment motor\/Fr (M14)<br>-Alignment plate home sensor\/Rr (PS6)<br>-Alignment plate home sensor\/Fr (PS9)<br>-FS control board (FSCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><th>Step<\/th><th>Action<\/th><th>Control signal<\/th><th>Location of electrical component<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub750iService\/en-US\/6369798795.html\">Initial check items<\/a><\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>PS6 I\/O check, sensor check<\/td><td>FSCB J21-10 (ON)<\/td><td>FS-540\/FS-540SD&nbsp;4-D<\/td><\/tr><tr><td>3<\/td><td>PS9 I\/O check, sensor check<\/td><td>FSCB J18-10 (ON)<\/td><td>FS-540\/FS-540SD&nbsp;6-D<\/td><\/tr><tr><td>4<\/td><td>M13 operation check<\/td><td>FSCB J21-1 to 4<\/td><td>FS-540\/FS-540SD&nbsp;4-D<\/td><\/tr><tr><td>5<\/td><td>M14 operation check<\/td><td>FSCB J18-1 to 4<\/td><td>FS-540\/FS-540SD&nbsp;5-D<\/td><\/tr><tr><td>6<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub750iService\/en-US\/6223494923.html\">Replace FSCB.<\/a> (Part# AAR5PPD401)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub750iService\/en-US\/9175896331.html\">(Link to the Field Service Manual)<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. When FS-539 or FS-539SD is installed Contents JAM type Misfeed at FS paper exit section (When&nbsp;FS-539&nbsp;or&nbsp;FS-539SD&nbsp;is installed) JAM code 72-77 JAM detection timing 72-77: The alignment home sensor (PS12\/PS13) is not turned OFF (unblocked) &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=72-77-bizhub-750i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;72-77 (bizhub 750i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1266],"epkb_post_type_1_tag":[],"class_list":["post-20528","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-7-750i-jam"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/20528","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=20528"}],"version-history":[{"count":2,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/20528\/revisions"}],"predecessor-version":[{"id":23493,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/20528\/revisions\/23493"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=20528"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=20528"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=20528"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}