{"id":20739,"date":"2020-06-24T13:34:48","date_gmt":"2020-06-24T13:34:48","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=20739"},"modified":"2023-12-13T18:38:48","modified_gmt":"2023-12-13T18:38:48","slug":"c0216-bizhub-750i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c0216-bizhub-750i","title":{"rendered":"C0216 (bizhub 750i)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C0216: External LCT up\/down abnormality (When LU-205 or LU-303 is installed)<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>The LU upper limit sensor (PS2) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>LCT<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>-LU upper limit sensor (PS2)<br>-LU lift-up motor (M1)<br>-LU drive board (LUDB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between M1-LUDB CN3 for proper connection and correct as necessary.<\/li><li>Check the connector of M1 for proper drive coupling and correct as necessary.<\/li><li>Check the connector between PS2-relay CN406-LUDB CN5 for proper connection and correct as necessary.<\/li><li>PS2 I\/O check, sensor check<ul><li>Control signal: LUDB CN5-3 (ON)<\/li><li>Location of electrical component: LU-205\/LU-303 4-G<\/li><\/ul><\/li><li>M1 load check<ul><li>Check code: 23<\/li><li>Multi code: 8<\/li><li>Control signal: LUDB CN3-4 (ON)<\/li><li>Location of electrical component: LU-205\/LU-303 3-G<\/li><\/ul><\/li><li>Replace M1. (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub750iService\/en-US\/8279667979.html\">LU-205<\/a>\u00a0\/\u00a0<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub750iService\/en-US\/8279870731.html\">LU-303<\/a>) (Part# A00JR74900)<\/li><li>Replace LUDB. (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub750iService\/en-US\/8279657739.html\">LU-205<\/a>\u00a0\/\u00a0<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub750iService\/en-US\/8279860491.html\">LU-303<\/a>) <br>LU-205 (Part# A8H6H00100)<br>LU-303 (Part# A8H6H00100)<\/li><\/ol>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub750iService\/en-US\/9257533451.html\">(Link to the Field Service Manual)<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. Contents Trouble type C0216: External LCT up\/down abnormality (When LU-205 or LU-303 is installed) Rank B Trouble detection condition The LU upper limit sensor (PS2) is not turned ON (blocked) even after the set &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c0216-bizhub-750i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C0216 (bizhub 750i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1296],"epkb_post_type_1_tag":[],"class_list":["post-20739","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c0-750i-trouble"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/20739","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=20739"}],"version-history":[{"count":2,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/20739\/revisions"}],"predecessor-version":[{"id":23549,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/20739\/revisions\/23549"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=20739"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=20739"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=20739"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}