{"id":20829,"date":"2020-06-24T15:26:37","date_gmt":"2020-06-24T15:26:37","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=20829"},"modified":"2023-12-13T18:35:08","modified_gmt":"2023-12-13T18:35:08","slug":"c1140-bizhub-750i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c1140-bizhub-750i","title":{"rendered":"C1140 (bizhub 750i)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E204653353339206F72204653353339534420697320696E7374616C6C6564\">When FS-539 or FS-539SD is installed<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C1140: Alignment motor\/Rr drive malfunction (When&nbsp;FS-539&nbsp;or&nbsp;FS-539SD&nbsp;is installed)<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>-The alignment plate home sensor\/Rr (PS13) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position.<br><br>-The alignment plate home sensor\/Rr (PS13) is not turned ON (blocked) after the set period of time has elapsed while the alignment motor\/Rr (M8) is energized when the plate returned to the home position.<br><br>-The plate does not reach the specified position within the set period of time.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>-Alignment motor\/Rr (M8)<br>-Alignment plate home sensor\/Rr (PS13)<br>-FS control board (FSCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between M8-relay CN19-FSCB J12 for proper connection and correct as necessary.<\/li><li>Check the connector of M8 for proper drive coupling and correct as necessary.<\/li><li>Check the connector between PS13-FSCB J9 for proper connection and correct as necessary.<\/li><li>PS13 I\/O check, sensor check<ul><li>Control signal: FSCB J9&lt;B>-12 (ON)<\/li><li>Location of electrical component:\u00a0FS-539\/FS-539SD\u00a010-C<\/li><\/ul><\/li><li>M8 operation check<ul><li>Control signal: FSCB J12-13 to 16<\/li><li>Location of electrical component:\u00a0FS-539\/FS-539SD\u00a07-C<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub750iService\/en-US\/6354278283.html\">Replace M8.<\/a> (Part# A3EPPP5500)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub750iService\/en-US\/6354222731.html\">Replace FSCB.<\/a> (Part# AAR4PP8201)<\/li><\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E204653353430206F72204653353430534420697320696E7374616C6C6564\">&nbsp;When FS-540 or FS-540SD is installed<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C1140: Alignment motor\/Rr drive malfunction (When&nbsp;FS-540&nbsp;or&nbsp;FS-540SD&nbsp;is installed)<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>-The alignment plate home sensor\/Rr (PS6) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position.<br><br>-The alignment plate home sensor\/Rr (PS6) is not turned ON (blocked) after the set period of time has elapsed while the alignment motor\/Rr (M13) is energized when the plate returned to the home position.<br><br>-The plate does not reach the specified position within the set period of time.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>-Alignment motor\/Rr (M13)<br>-Alignment plate home sensor\/Rr (PS6)<br>-FS control board (FSCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between M13-relay CN3-FSCB J21 for proper connection and correct as necessary.<\/li><li>Check the connector of M13 for proper drive coupling and correct as necessary.<\/li><li>Check the connector between PS6-relay CN4-relay CN3-FSCB J21 for proper connection and correct as necessary.<\/li><li>PS6 I\/O check, sensor check<ul><li>Control signal: FSCB J21-10 (ON)<\/li><li>Location of electrical component:\u00a0FS-540\/FS-540SD\u00a04-D<\/li><\/ul><\/li><li>M13 operation check<ul><li>Control signal: FSCB J21-1 to 4<\/li><li>Location of electrical component:\u00a0FS-540\/FS-540SD\u00a04-D<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub750iService\/en-US\/6223579659.html\">Replace M13.<\/a> (Part# A87HPPAD00)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub750iService\/en-US\/6223494923.html\">Replace FSCB.<\/a> (Part# AAR5PPD401)<\/li><\/ol>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub750iService\/en-US\/9258729355.html\">(Link to the Field Service Manual)<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. When FS-539 or FS-539SD is installed Contents Trouble type C1140: Alignment motor\/Rr drive malfunction (When&nbsp;FS-539&nbsp;or&nbsp;FS-539SD&nbsp;is installed) Rank B Trouble detection condition -The alignment plate home sensor\/Rr (PS13) is not turned OFF (unblocked) after the &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c1140-bizhub-750i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C1140 (bizhub 750i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1297],"epkb_post_type_1_tag":[],"class_list":["post-20829","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c1-750i-trouble"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/20829","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=20829"}],"version-history":[{"count":2,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/20829\/revisions"}],"predecessor-version":[{"id":23575,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/20829\/revisions\/23575"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=20829"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=20829"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=20829"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}