{"id":20958,"date":"2020-06-29T18:43:57","date_gmt":"2020-06-29T18:43:57","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=20958"},"modified":"2023-12-13T18:33:30","modified_gmt":"2023-12-13T18:33:30","slug":"c2650-bizhub-c750i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c2650-bizhub-c750i","title":{"rendered":"C2650 (bizhub C750i)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C2650: Main backup media access error<\/td><\/tr><tr><td>Rank<\/td><td>C<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>-The re-written data, which has been read out, checked and founded as error, is read out again and found as error.<br><br>-The error was found when reading out the counter value.<br><br>-The main body detects that the back up board is not mounted.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>-Backup board (ERB)<br>-CPU board (CPUB)<br>-Base board (BASEB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between ERB CN1-BASEB CN27E for proper connection and correct as necessary.<\/li><li>Check CPUB for proper installation and correct as necessary.<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC750iService\/en-US\/9292884491.html\">Replace CPUB.<\/a> (Part# ACKNH02P03)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC750iService\/en-US\/9292823179.html\">Replace BASEB.<\/a> (Part# ACKNH02101)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC750iService\/en-US\/9292978955.html\">Replace ERB.<\/a> (Part# AA2JH00C00)<br>1. Replace the current ERB with a new one.<br>2. Replace the following components with new ones.<br>When the transfer belt unit and the fusing unit have been replaced with new ones, perform [Service Mode] -> [Counter] -> [Life] -> [New Release]. When the transfer roller has been replaced with a new one, perform the counter reset in [Service Mode] -> [Counter] -> [Life].<br><ul><li>Developing unit<br>(C Part# ACV80KD, M Part# ACV80ED, Y Part# ACV808D, K Part# ACV803D)<\/li><li>Drum unit<br>(CMY ACV80TE \/ K Part# ACV80RE)<\/li><li>Toner cartridge<br>(C Part# ACP8430,M Part# ACP8330, Y Part# ACP8230, K Part# ACP8130)<\/li><li>Transfer belt unit<br>(Part# AA2JR73100)<\/li><li>Fusing unit<br>(Part# AA7NR70200)<\/li><li>Transfer roller<br>(Part# AA7NR70400)<\/li><li>Feed roller<br>Tray 1-3: (Part# A64J564101)<br>Manual bypass tray: (Part# A00F623201)<br>Dual Scan Document Feeder: (Part# A00J563600)<\/li><li>pick-up roller<br>Tray 1-3: (Part# A64J564201)<br>Manual bypass tray: (Part# A5C1562200)<br>Dual Scan Document Feeder: (Part# 9J07330102)<\/li><li> separation roller (including options)<br>Tray 1-3: (Part# AA2J560000)<br>Manual bypass tray: (Part# AA7N591100)<br>Dual Scan Document Feeder: (Part# 9J07340901)<br><br>3. Turn ON the main power switch and check to see that warm-up is started.<br>Make sure that malfunction codes other than C2650 or improper IU\/TC placement is not detected.<br>4. Make the specified readjustments.<\/li><\/ul><\/li><li>If the above actions do not solve the problem, contact KM.<\/li><\/ol>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC750iService\/en-US\/9259488779.html\">(Link to the Field Service Manual)<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. Contents Trouble type C2650: Main backup media access error Rank C Trouble detection condition -The re-written data, which has been read out, checked and founded as error, is read out again and found as &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c2650-bizhub-c750i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C2650 (bizhub C750i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1283],"epkb_post_type_1_tag":[],"class_list":["post-20958","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c2-c750i-trouble"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/20958","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=20958"}],"version-history":[{"count":4,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/20958\/revisions"}],"predecessor-version":[{"id":22619,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/20958\/revisions\/22619"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=20958"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=20958"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=20958"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}