{"id":21580,"date":"2020-07-01T15:05:01","date_gmt":"2020-07-01T15:05:01","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=21580"},"modified":"2023-12-13T17:49:18","modified_gmt":"2023-12-13T17:49:18","slug":"cd2d1-bizhub-750i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=cd2d1-bizhub-750i","title":{"rendered":"CD2D1 (bizhub 750i)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>CD2D1: VLAN setting configuration error<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>At start up of the MFP, the reception condition of VLAN setting activation is not satisfied.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>-Storage board (STRGB)<br>-Backup board (ERB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check if all VLAN setting reception conditions are satisfied.<\/li><\/ol>\n\n\n\n<ul class=\"wp-block-list\"><li>The storage board (STRGB) must be installed.<\/li><li>If the IC card reader is connected, the LDD of AU-201S has been installed.<\/li><li>The software SW12 (bit1) has been set to &#8220;PKI unsupported&#8221; (0x00). (PKI mode setting unavailable)<\/li><li>Service Mode -&gt; [Billing Setting] -&gt; [Management Function Choice] is set to &#8220;Unset&#8221;.<\/li><li>&#8220;TCP\/IP\u201d of Utility -&gt; [Administrator] -&gt; [Network] -&gt; [TCP\/IP Setting] -&gt; [TCP\/IP Setting1] is set to &#8220;ON\u201d.<\/li><li>&#8220;Network I\/F Configuration\u201d of Utility -&gt; [Administrator] -&gt; [Network] -&gt; [Network I\/F Configuration] is set to other than &#8220;Wireless Only\u201d.<\/li><\/ul>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub750iService\/en-US\/9262310155.html\">(Link to the Field Service Manual)<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. Contents Trouble type CD2D1: VLAN setting configuration error Rank B Trouble detection condition At start up of the MFP, the reception condition of VLAN setting activation is not satisfied. Trouble isolation &#8211; Relevant electrical &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=cd2d1-bizhub-750i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;CD2D1 (bizhub 750i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1309],"epkb_post_type_1_tag":[],"class_list":["post-21580","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-cd-750i-trouble"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/21580","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=21580"}],"version-history":[{"count":2,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/21580\/revisions"}],"predecessor-version":[{"id":23824,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/21580\/revisions\/23824"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=21580"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=21580"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=21580"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}