{"id":21800,"date":"2020-07-02T13:44:58","date_gmt":"2020-07-02T13:44:58","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=21800"},"modified":"2023-12-13T17:45:58","modified_gmt":"2023-12-13T17:45:58","slug":"72-17-bizhub-650i-550i-450i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=72-17-bizhub-650i-550i-450i","title":{"rendered":"72-17 (bizhub 650i\/550i\/450i)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E20465335333320697320696E7374616C6C6564\">When FS-533 is installed<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>JAM type<\/td><td>Misfeed at FS transport section (When&nbsp;FS-533&nbsp;is installed) <\/td><\/tr><tr><td>JAM code<\/td><td>72-17<\/td><\/tr><tr><td>JAM detection timing<\/td><td>72-17: The paper feed sensor (PS101) is not turn OFF even after the lapse of a given period of time after the leading edge of the paper has turned ON PS101.<\/td><td><\/td><\/tr><tr><td>Misfeed processing location<\/td><td>Finisher paper feed section<\/td><\/tr><tr><td>Relevant parts<\/td><td>-Paper conveyance motor (M101)<br>-Paper feed sensor (PS101)<br>-FS control board (FSCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><th>Step<\/th><th>Action<\/th><th>Control signal<\/th><th>Location of electrical component<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/6369798795.html\">Initial check items<\/a><\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>PS101 I\/O check, sensor check<\/td><td>FSCB CN111<\/td><td>FS-533&nbsp;7-D to E<\/td><\/tr><tr><td>3<\/td><td>M101 operation check<\/td><td>FSCB CN101<\/td><td>FS-533&nbsp;6-J<\/td><\/tr><tr><td>4<\/td><td>FSCB CP101 conduction check<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>5<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/6222025227.html\">Replace FSCB.<\/a><br>(Part# A2YUPPH901 for Model No. A2YU-WY1 or Part # A2YUPPXN00 for Model No. A2YU-WY2)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E204653353339206F72204653353339534420697320696E7374616C6C6564\">&nbsp;When FS-539 or FS-539SD is installed<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>JAM type<\/td><td>Misfeed at FS transport section (When FS-539 or FS-539SD is installed)<\/td><\/tr><tr><td>JAM code<\/td><td><\/td><\/tr><tr><td>JAM detection timing<\/td><td>The FNS entrance sensor (PS4) is not turned OFF even after the lapse of a given period of time after the leading edge of the paper has turned ON PS4.<\/td><td><\/td><\/tr><tr><td>Misfeed processing location<\/td><td>Front door<\/td><\/tr><tr><td>Relevant parts<\/td><td>-FNS entry transport motor (M2)<br>-FNS entrance sensor (PS4)<br>-FS control board (FSCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><th>Step<\/th><th>Action<\/th><th>Control signal<\/th><th>Location of electrical component<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/6369798795.html\">Initial check items<\/a><\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>PS4 I\/O check, sensor check<\/td><td>FSCB J4&lt;B&gt;-9 (ON)<\/td><td>FS-539\/FS-539SD&nbsp;15-C<\/td><\/tr><tr><td>3<\/td><td>M2 operation check<\/td><td>FSCB J9&lt;A&gt;-1 to 4<\/td><td>FS-539\/FS-539SD&nbsp;12-C<\/td><\/tr><tr><td>4<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/6354222731.html\">Replace FSCB.<\/a> (Part# AAR4PP8201)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E204653353430206F72204653353430534420697320696E7374616C6C6564\">&nbsp;When FS-540 or FS-540SD is installed<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>JAM type<\/td><td>Misfeed at FS transport section (When FS-540 or FS-540SD is installed)<\/td><\/tr><tr><td>JAM code<\/td><td>72-17<\/td><\/tr><tr><td>JAM detection timing<\/td><td>72-17: The FNS entrance sensor (PS34) is not turned OFF even after the lapse of a given period of time after the leading edge of the paper has turned ON PS34.<\/td><td><\/td><\/tr><tr><td>Misfeed processing location<\/td><td>Front door<\/td><\/tr><tr><td>Relevant parts<\/td><td>-FNS entry transport motor (M20)<br>-FNS entrance sensor (PS34)<br>-FS control board (FSCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><th>Step<\/th><th>Action<\/th><th>Control signal<\/th><th>Location of electrical component<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/6369798795.html\">Initial check items<\/a><\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>PS34 I\/O check, sensor check<\/td><td>FSCB J8&lt;A&gt;-5 (ON)<\/td><td>FS-540\/FS-540SD&nbsp;7-D<\/td><\/tr><tr><td>3<\/td><td>M20 operation check<\/td><td>FSCB J8-8 to 11<\/td><td>FS-540\/FS-540SD&nbsp;7-D<\/td><\/tr><tr><td>4<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/6223494923.html\">Replace FSCB.<\/a> (Part# AAR5PPD401)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/9590154507.html\">(Link to the Field Service Manual)<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. When FS-533 is installed Contents JAM type Misfeed at FS transport section (When&nbsp;FS-533&nbsp;is installed) JAM code 72-17 JAM detection timing 72-17: The paper feed sensor (PS101) is not turn OFF even after the lapse &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=72-17-bizhub-650i-550i-450i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;72-17 (bizhub 650i\/550i\/450i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1320],"epkb_post_type_1_tag":[],"class_list":["post-21800","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-7-650i-550i-450i-jam"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/21800","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=21800"}],"version-history":[{"count":2,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/21800\/revisions"}],"predecessor-version":[{"id":22877,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/21800\/revisions\/22877"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=21800"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=21800"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=21800"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}