{"id":21824,"date":"2020-07-02T14:58:52","date_gmt":"2020-07-02T14:58:52","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=21824"},"modified":"2023-12-13T17:45:58","modified_gmt":"2023-12-13T17:45:58","slug":"72-49-bizhub-650i-550i-450i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=72-49-bizhub-650i-550i-450i","title":{"rendered":"72-49 (bizhub 650i\/550i\/450i)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>JAM type<\/td><td>Misfeed at PI section (When&nbsp;FS-540+PI-507&nbsp;or&nbsp;FS-540SD+PI-507&nbsp;is installed)<\/td><\/tr><tr><td>JAM code<\/td><td>72-49<\/td><\/tr><tr><td>JAM detection timing<\/td><td>72-49: The paper entrance sensor\/Up (PS201) is not turned OFF (unblocked) even after the lapse of a given period of time after the leading edge of the paper has turned ON (blocked) PS201.<\/td><td><\/td><\/tr><tr><td>Misfeed processing location<\/td><td>Upper door<\/td><\/tr><tr><td>Relevant parts<\/td><td>-Transport motor (M203)<br>-Registration clutch (CL203)<br>-Paper entrance sensor\/Up (PS201)<br>-PI drive board (PIDB)<br>-FS control board (FSCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><th>Step<\/th><th>Action<\/th><th>Control signal<\/th><th>Location of electrical component<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/6369798795.html\">Initial check items<\/a><\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>PS201 I\/O check, sensor check<\/td><td>PIDB CN53&lt;A&gt;-2 (ON)<\/td><td>PI-507&nbsp;10-C<\/td><\/tr><tr><td>3<\/td><td>CL203 operation check<\/td><td>PIDB CN57-1 (ON)<\/td><td>PI-507&nbsp;5 to 6-C<\/td><\/tr><tr><td>4<\/td><td>M203 operation check<\/td><td>PIDB CN57-1 to 11<\/td><td>PI-507&nbsp;5-C<\/td><\/tr><tr><td>5<\/td><td>PIDB ICP4 conduction check<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>6<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/6223101323.html\">Replace PIDB.<\/a> (Part# A8C6H00101)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>7<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/6223494923.html\">Replace FSCB.<\/a> (Part# AAR5PPD401)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/9589938571.html\">(Link to the Field Service Manual)<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. Contents JAM type Misfeed at PI section (When&nbsp;FS-540+PI-507&nbsp;or&nbsp;FS-540SD+PI-507&nbsp;is installed) JAM code 72-49 JAM detection timing 72-49: The paper entrance sensor\/Up (PS201) is not turned OFF (unblocked) even after the lapse of a given period &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=72-49-bizhub-650i-550i-450i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;72-49 (bizhub 650i\/550i\/450i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1320],"epkb_post_type_1_tag":[],"class_list":["post-21824","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-7-650i-550i-450i-jam"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/21824","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=21824"}],"version-history":[{"count":2,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/21824\/revisions"}],"predecessor-version":[{"id":22891,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/21824\/revisions\/22891"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=21824"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=21824"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=21824"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}