{"id":21922,"date":"2020-07-06T14:01:30","date_gmt":"2020-07-06T14:01:30","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=21922"},"modified":"2023-12-13T17:44:10","modified_gmt":"2023-12-13T17:44:10","slug":"c0107-bizhub-650i-550i-450i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c0107-bizhub-650i-550i-450i","title":{"rendered":"C0107 (bizhub 650i\/550i\/450i)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E205043313136206F7220504332313620697320696E7374616C6C6564\">When PC-116 or PC-216 is installed<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C0107: Tray 3 vertical transport motor turning at abnormal timing (When&nbsp;PC-116&nbsp;or&nbsp;PC-216&nbsp;is installed)<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>-The control circuit detects motor failure to turn while the motor is turning.<br><br>-The control circuit detects motor turning while the motor remains stationary.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>-Tray 3 vertical transport motor (M112)<br>-PC control board (PCCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between M112-PCCB CN5 for proper connection and correct as necessary.<\/li><li>Check the connector of M112 for proper drive coupling and correct as necessary.<\/li><li>M112 load check<ul><li>Check code: 28<\/li><li>Multi code:<br>6, 7, 8, 9 (bizhub\u00a0650i)<br>6, 8, 9 (bizhub\u00a0550i)<\/li><li>6, 7, 9 (bizhub\u00a0450i)<\/li><li>Control signal: PCCB CN5-13 (CW\/CCW)<\/li><li>Location of electrical component:\u00a0PC-116\/PC-216\u00a03 to 4-C<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/6354125067.html\">Replace M112.<\/a> (Part# A2XMM11000)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/6354111243.html\">Replace PCCB.<\/a> <br>PC-116 (Part# AAV5H00101)<br>PC-216 (Part# AAV5H00201)<\/li><\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E20504334313620697320696E7374616C6C6564\">&nbsp;When PC-416 is installed<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C0107: Transfer LCT vertical transport motor turning at abnormal timing (When&nbsp;PC-416&nbsp;is installed)<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>-The control circuit detects motor failure to turn while the motor is turning.<br><br>-The control circuit detects motor turning while the motor remains stationary.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>-Vertical transport motor (M132)<br>-PC control board (PCCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between M132-PCCB CN5 for proper connection and correct as necessary.<\/li><li>Check the connector of M132 for proper drive coupling and correct as necessary.<\/li><li>M132 load check<ul><li>Check code: 28<\/li><li>Multi code:<\/li><li>21, 22, 23, 24 (bizhub\u00a0650i)<\/li><li>21, 23, 24 (bizhub\u00a0550i)<\/li><li>21, 22, 24 (bizhub\u00a0450i)<\/li><li>Control signal: PCCB CN5-13 (CW\/CCW)<\/li><li>Location of electrical component:\u00a0PC-416\u00a04-J<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/6354160267.html\">Replace M132.<\/a> (Part# A2XMM11000)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/6354152587.html\">Replace PCCB.<\/a> (Part# AAV5H00300)<\/li><\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E20504334313720697320696E7374616C6C6564\">&nbsp;When PC-417 is install<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E20504334313720697320696E7374616C6C6564\">&nbsp;When PC-417 is installed<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C0107: Intermediate motor turning at abnormal timing (When&nbsp;PC-417&nbsp;is installed)<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>-The control circuit detects motor failure to turn while the motor is turning.<br><br>-The control circuit detects motor turning while the motor remains stationary.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>-Intermediate motor (M151)<br>-PC control board (PCCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between M151-relay CN73-PCCB CN20 for proper connection and correct as necessary.<\/li><li>Check the connector of M151 for proper drive coupling and correct as necessary.<\/li><li>M151 load check<ul><li>Check code: 28<\/li><li>Multi code:<\/li><li>56, 57, 58, 59 (bizhub\u00a0650i)<\/li><li>56, 58, 59 (bizhub\u00a0550i)<\/li><li>56, 57, 59 (bizhub\u00a0450i)<\/li><li>Control signal: PCCB CN20-1 to 3<\/li><li>Location of electrical component:\u00a0PC-417\u00a07-K<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/8810132107.html\">Replace M151.<\/a> (Part# AAV5M11000)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/8809421323.html\">Replace PCCB.<\/a> (Part# AAV5H01401)<\/li><\/ol>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/9591977611.html\">(Link to the Field Service Manual)<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. When PC-116 or PC-216 is installed Contents Trouble type C0107: Tray 3 vertical transport motor turning at abnormal timing (When&nbsp;PC-116&nbsp;or&nbsp;PC-216&nbsp;is installed) Rank B Trouble detection condition -The control circuit detects motor failure to turn &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c0107-bizhub-650i-550i-450i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C0107 (bizhub 650i\/550i\/450i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1325],"epkb_post_type_1_tag":[],"class_list":["post-21922","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c0-650i-550i-450i-trouble"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/21922","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=21922"}],"version-history":[{"count":2,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/21922\/revisions"}],"predecessor-version":[{"id":22948,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/21922\/revisions\/22948"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=21922"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=21922"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=21922"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}