{"id":21935,"date":"2020-07-06T14:26:57","date_gmt":"2020-07-06T14:26:57","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=21935"},"modified":"2023-12-13T17:43:10","modified_gmt":"2023-12-13T17:43:10","slug":"c0208-bizhub-650i-550i-450i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c0208-bizhub-650i-550i-450i","title":{"rendered":"C0208 (bizhub 650i\/550i\/450i)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E20504332313620697320696E7374616C6C6564\">When PC-216 is installed<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C0208: Tray 4 feeder up\/down abnormality (When&nbsp;PC-216&nbsp;is installed)<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>The tray 4 upper limit sensor (PS126) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>Tray 4<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>-Tray 4 lift-up motor (M123)<br>-Tray 4 upper limit sensor (PS126)<br>-PC control board (PCCB)<br>-CPU board (CPUB)<br>-Base board (BASEB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/6354103051.html\">Remove the tray<\/a>\u00a0and check to see if a piece of paper is not left inside the machine.<\/li><li>Check the connector between M123-PCCB CN8C for proper connection and correct as necessary.<\/li><li>Check the connector of M123 for proper drive coupling and correct as necessary.<\/li><li>Check the connector between PS126-relay CN47-PCCB CN7C for proper connection and correct as necessary.<\/li><li>Check CPUB for proper installation and correct as necessary.<\/li><li>PS126 I\/O check, sensor check<ul><li>Control signal: PCCB CN7C-3 (ON)<\/li><li>Location of electrical component:\u00a0PC-216\u00a08-K<\/li><\/ul><\/li><li>M123 load check<ul><li>Check code: 23<\/li><li>Multi code: 7<\/li><li>Control signal: PCCB CN8C-8 to 9<\/li><li>Location of electrical component:\u00a0PC-216\u00a05-K<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/6354127115.html\">Replace M123.<\/a> (Part# 9J06M10300)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/6354111243.html\">Replace PCCB.<\/a> (Part# AAV5H00201)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/10395408011.html\">Replace CPUB.<\/a><br>650i\/550i (Part# AC74H02P03)<br>450i (Part# AC76H02P02)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/9030648075.html\">Replace BASEB.<\/a> (Part# AC74H02101)<\/li><\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E20504334313720697320696E7374616C6C6564\">&nbsp;When PC-417 is installed<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C0208: Tray 4 feeder up\/down abnormality (When&nbsp;PC-417&nbsp;is installed)<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>The tray 4 upper limit sensor (PS166) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>Tray 4<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>-Tray 4 lift-up motor (M144)<br>-Tray 4 upper limit sensor (PS166)<br>-PC control board (PCCB)<br>-CPU board (CPUB)<br>-Base board (BASEB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/8809337483.html\">Remove the tray<\/a>\u00a0and check to see if a piece of paper is not left inside the machine.<\/li><li>Check the connector between M144-PCCB CN6 for proper connection and correct as necessary.<\/li><li>Check the connector of M144 for proper drive coupling and correct as necessary.<\/li><li>Check the connector between PS166-relay CN47-PCCB CN4 for proper connection and correct as necessary.<\/li><li>Check CPUB for proper installation and correct as necessary.<\/li><li>PS166 I\/O check, sensor check<ul><li>Control signal: PCCB CN4-3 (ON)<\/li><li>Location of electrical component:\u00a0PC-417\u00a04-C<\/li><\/ul><\/li><li>M144 load check<ul><li>Check code: 23<\/li><li>Multi code: 7<\/li><li>Control signal: PCCB CN6-9 to 10<\/li><li>Location of electrical component:\u00a0PC-417\u00a05-K<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/6368573963.html\">Replace M144.<\/a> (Part# A2X0M12101)<\/li><li>PCCB PS301 conduction check<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/8809421323.html\">Replace PCCB.<\/a> (Part# AAV5H01401)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/10395408011.html\">Replace CPUB.<\/a><br>650i\/550i (Part# AC74H02P03)<br>450i (Part# AC76H02P02)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/9030648075.html\">Replace BASEB.<\/a> (Part# AC74H02101)<\/li><\/ol>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/9592234763.html\">(Link to the Field Service Manual)<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. When PC-216 is installed Contents Trouble type C0208: Tray 4 feeder up\/down abnormality (When&nbsp;PC-216&nbsp;is installed) Rank B Trouble detection condition The tray 4 upper limit sensor (PS126) is not turned ON (blocked) even after &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c0208-bizhub-650i-550i-450i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C0208 (bizhub 650i\/550i\/450i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1325],"epkb_post_type_1_tag":[],"class_list":["post-21935","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c0-650i-550i-450i-trouble"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/21935","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=21935"}],"version-history":[{"count":4,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/21935\/revisions"}],"predecessor-version":[{"id":23355,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/21935\/revisions\/23355"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=21935"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=21935"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=21935"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}