{"id":21957,"date":"2020-07-06T14:48:14","date_gmt":"2020-07-06T14:48:14","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=21957"},"modified":"2023-12-13T17:43:09","modified_gmt":"2023-12-13T17:43:09","slug":"c1103-bizhub-650i-550i-450i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c1103-bizhub-650i-550i-450i","title":{"rendered":"C1103 (bizhub 650i\/550i\/450i)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E20465335333320697320696E7374616C6C6564\">When FS-533 is installed<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C1103: Alignment motor\/Fr drive malfunction (When&nbsp;FS-533&nbsp;is installed)<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>-The alignment plate home sensor\/Fr (PS108) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position.<br><br>-The alignment plate home sensor\/Fr (PS108) is not turned ON (blocked) after the set period of time has elapsed after the alignment motor\/Fr (M105) is energized when the plate returned to the home position.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>-Alignment motor\/Fr (M105)<br>-Alignment plate home sensor\/Fr (PS108)<br>-FS control board (FSCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between M105-FSCB CN102 for proper connection and correct as necessary.<\/li><li>Check the connector of M105 for proper drive coupling and correct as necessary.<\/li><li>Check the connector between PS108-FSCB CN102 for proper connection and correct as necessary.<\/li><li>PS108 I\/O check, sensor check<ul><li>Control signal: FSCB CN102<\/li><li>Location of electrical component:\u00a0FS-533\u00a07-J<\/li><\/ul><\/li><li>M105 operation check<ul><li>Control signal: FSCB CN102<\/li><li>Location of electrical component:\u00a0FS-533\u00a07-J<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/6222095883.html\">Replace M105.<\/a> (Part# A2YUPPW600)<\/li><li>FSCB CP105 conduction check<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/6222025227.html\">Replace FSCB.<\/a> (Part# A2YUPPH901 for Model No. A2YU-WY1 or Part # A2YUPPXN00 for Model No. A2YU-WY2)<\/li><\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E204653353339206F72204653353339534420697320696E7374616C6C6564\">&nbsp;When FS-539 or FS-539SD is installed<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C1103: Alignment motor\/Fr drive malfunction (When&nbsp;FS-539&nbsp;or&nbsp;FS-539SD&nbsp;is installed)<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>-The alignment plate home sensor\/Fr (PS12) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position.<br><br>-The alignment plate home sensor\/Fr (PS12) is not turned ON (blocked) after the set period of time has elapsed after the alignment motor\/Fr (M7) is energized when the plate returned to the home position.The alignment plate\/Fr does not reach the specified position within the set period of time.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>-Alignment motor\/Fr (M7)<br>-Alignment plate home sensor\/Fr (PS12)<br>-FS control board (FSCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between M7-relay CN13-FSCB J4 for proper connection and correct as necessary.<\/li><li>Check the connector of M7 for proper drive coupling and correct as necessary.<\/li><li>Check the connector between PS12-FSCB J4 for proper connection and correct as necessary.<\/li><li>PS12 I\/O check, sensor check<ul><li>Control signal: FSCB J4&lt;B>-4 (ON)<\/li><li>Location of electrical component:\u00a0FS-539\/FS-539SD\u00a014-C<\/li><\/ul><\/li><li>M7 operation check<ul><li>Control signal: FSCB J4&lt;A>-5 to 8<\/li><li>Location of electrical component:\u00a0FS-539\/FS-539SD\u00a013 to 14-C<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/6354270347.html\">Replace M7.<\/a> (Part# A3EPPP5500)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/6354222731.html\">Replace FSCB.<\/a> (Part# AAR4PP8201)<\/li><\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E204653353430206F72204653353430534420697320696E7374616C6C6564\">&nbsp;When FS-540 or FS-540SD is installed<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C1103: Alignment motor\/Fr drive malfunction (When&nbsp;FS-540&nbsp;or&nbsp;FS-540SD&nbsp;is installed)<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>-The alignment plate home sensor\/Fr (PS9) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position.<br><br>-The alignment plate home sensor\/Fr (PS9) is not turned ON (blocked) after the set period of time has elapsed after the alignment motor\/Fr (M14) is energized when the plate returned to the home position.The alignment plate\/Fr does not reach the specified position within the set period of time.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>-Alignment motor\/Fr (M14)<br>-Alignment plate home sensor\/Fr (PS9)<br>-FS control board (FSCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between M14-relay CN5-FSCB J18 for proper connection and correct as necessary.<\/li><li>Check the connector of M14 for proper drive coupling and correct as necessary.<\/li><li>Check the connector between PS9-relay CN5-FSCB J18 for proper connection and correct as necessary.<\/li><li>PS9 I\/O check, sensor check<ul><li>Control signal: FSCB J18-10 (ON)<\/li><li>Location of electrical component:\u00a0FS-540\/FS-540SD\u00a06-D<\/li><\/ul><\/li><li>M14 operation check<ul><li>Control signal: FSCB J18-1 to 4<\/li><li>Location of electrical component:\u00a0FS-540\/FS-540SD\u00a05-D<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/6223589899.html\">Replace M14.<\/a> (Part# A87HPPAD00)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/6223494923.html\">Replace FSCB.<\/a> (Part# AAR5PPD401)<\/li><\/ol>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub650iService\/en-US\/9592813451.html\">(Link to the Field Service Manual)<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. When FS-533 is installed Contents Trouble type C1103: Alignment motor\/Fr drive malfunction (When&nbsp;FS-533&nbsp;is installed) Rank B Trouble detection condition -The alignment plate home sensor\/Fr (PS108) is not turned OFF (unblocked) after the set period &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c1103-bizhub-650i-550i-450i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C1103 (bizhub 650i\/550i\/450i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1326],"epkb_post_type_1_tag":[],"class_list":["post-21957","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c1-650i-550i-450i-trouble"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/21957","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=21957"}],"version-history":[{"count":2,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/21957\/revisions"}],"predecessor-version":[{"id":22970,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/21957\/revisions\/22970"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=21957"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=21957"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=21957"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}