{"id":24024,"date":"2020-09-18T12:43:41","date_gmt":"2020-09-18T12:43:41","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=24024"},"modified":"2023-12-13T16:48:17","modified_gmt":"2023-12-13T16:48:17","slug":"c0206-bizhub-360i-300i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c0206-bizhub-360i-300i","title":{"rendered":"C0206 (bizhub 360i\/300i)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E205043313136206F7220504332313620697320696E7374616C6C6564\">When PC-116 or PC-216 is installed<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C0206: Tray 3 feeder up\/down abnormality (When&nbsp;PC-116&nbsp;or&nbsp;PC-216&nbsp;is installed)<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>The tray 3 upper limit sensor (PS116) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>Tray 3<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>-Tray 3 lift-up motor (M113)<br>-Tray 3 upper limit sensor (PS116)<br>-PC control board (PCCB)<br>-CPU board (CPUB)<br>-Base board (BASEB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub360iService\/en-US\/6354103051.html\">Remove the tray<\/a>\u00a0and check to see if a piece of paper is not left inside the machine.<\/li><li>Check the connector between M113-PCCB CN6C for proper connection and correct as necessary.<\/li><li>Check the connector of M113 for proper drive coupling and correct as necessary.<\/li><li>Check the connector between PS116-relay CN24-PCCB CN4 for proper connection and correct as necessary.<\/li><li>Check CPUB for proper installation and correct as necessary.<\/li><li>PS116 I\/O check, sensor check<ul><li>Control signal: PCCB CN4-3 (ON)<\/li><li>Location of electrical component:\u00a0PC-116\/PC-216\u00a07-C<\/li><\/ul><\/li><li>M113 load check<ul><li>Check code: 23<\/li><li>Multi code: 6<\/li><li>Control signal: PCCB CN6C-8 to 9<\/li><li>Location of electrical component:\u00a0PC-116\/PC-216\u00a02-C<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub360iService\/en-US\/6354127115.html\">Replace M113.<\/a> (Part# 9J06M10300)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub360iService\/en-US\/6354111243.html\">Replace PCCB.<\/a> <br>PC-116 (Part# AAV5H00101)<br>PC-216 (Part# AAV5H00201)<br><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub360iService\/en-US\/10395900555.html\">Replace CPUB.<\/a> (Part# AC77H02P02)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub360iService\/en-US\/9028040715.html\">Replace BASEB.<\/a> (Part# AC77H02101)<\/li><\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E20504334313720697320696E7374616C6C6564\">&nbsp;When PC-417 is installed<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C0206: Tray 3 feeder up\/down abnormality (When&nbsp;PC-417&nbsp;is installed)<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>The tray 3 upper limit sensor (PS156) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>Tray 3<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>-Tray 3 lift-up motor (M143)<br>-Tray 3 upper limit sensor (PS156)<br>-PC control board (PCCB)<br>-CPU board (CPUB)<br>-Base board (BASEB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub360iService\/en-US\/6368548107.html\">Remove the tray<\/a>\u00a0and check to see if a piece of paper is not left inside the machine.<\/li><li>Check the connector between M143-PCCB CN6 for proper connection and correct as necessary.<\/li><li>Check the connector of M143 for proper drive coupling and correct as necessary.<\/li><li>Check the connector between PS156-relay CN25-PCCB CN7 for proper connection and correct as necessary.<\/li><li>Check CPUB for proper installation and correct as necessary.<\/li><li>PS156 I\/O check, sensor check<ul><li>Control signal: PCCB CN7-9 (ON)<\/li><li>Location of electrical component:\u00a0PC-417\u00a04-C<\/li><\/ul><\/li><li>M143 load check<ul><li>Check code: 23<\/li><li>Multi code: 6<\/li><li>Control signal: PCCB CN6-4 to 5<\/li><li>Location of electrical component:\u00a0PC-417\u00a05-K<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub360iService\/en-US\/6368561675.html\">Replace M143.<\/a> (Part# A2X0M12101)<\/li><li>PCCB PS300 conduction check<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub360iService\/en-US\/8809421323.html\">Replace PCCB.<\/a> (Part# AAV5H01401)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub360iService\/en-US\/10395900555.html\">Replace CPUB.<\/a> (Part# AC77H02P02)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub360iService\/en-US\/9028040715.html\">Replace BASEB.<\/a> (Part# AC77H02101)<\/li><\/ol>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub360iService\/en-US\/9611646859.html\">(Link to the Field Service Manual)<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. When PC-116 or PC-216 is installed Contents Trouble type C0206: Tray 3 feeder up\/down abnormality (When&nbsp;PC-116&nbsp;or&nbsp;PC-216&nbsp;is installed) Rank B Trouble detection condition The tray 3 upper limit sensor (PS116) is not turned ON (blocked) &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c0206-bizhub-360i-300i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C0206 (bizhub 360i\/300i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1353],"epkb_post_type_1_tag":[],"class_list":["post-24024","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c0-360i-300i-trouble"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/24024","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=24024"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/24024\/revisions"}],"predecessor-version":[{"id":24025,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/24024\/revisions\/24025"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=24024"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=24024"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=24024"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}