{"id":243,"date":"2019-04-15T16:43:31","date_gmt":"2019-04-15T16:43:31","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=243"},"modified":"2023-12-27T18:19:19","modified_gmt":"2023-12-27T18:19:19","slug":"c1144-bizhub-c658-c558-c458","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c1144-bizhub-c658-c558-c458","title":{"rendered":"C1144 (bizhub C658\/C558\/C458)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"436F6E74656E7473\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C1144: Pre-eject drive motor drive malfunction<\/td><td><\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><td><\/td><\/tr><tr><td>Trouble detection condition<\/td><td>&lt;When FS-536 or FS-536SD is installed&gt;<\/td><td>\u2022The pre-eject home sensor (PS21) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed after the pre-eject drive motor (M9) is turned ON. <br>\u2022 The pre-eject away sensor (PS22) is not turned ON (blocked) or OFF (unblocked) even after the set period of time has elapsed after the pre-eject drive motor (M9) is turned ON.<\/td><td><\/td><\/tr><tr><td><\/td><td> &lt;When FS-537 or FS-537SD is installed> <\/td><td> <br>The trail edge stopper home sensor (PS31) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed after the pre-eject drive motor (M2) is turned ON. <\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><td><\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>&lt;When FS-536 or FS-536SD is installed&gt;<\/td><td>\u2022Pre-eject drive motor (M9) <br>\u2022 Pre-eject home sensor (PS21) <br>\u2022 Pre-eject away sensor (PS22) <br>\u2022 FS control board (FSCB)<\/td><td><\/td><\/tr><tr><td><\/td><td> <br>&lt;When FS-537 or FS-537SD is installed> <\/td><td>\u2022Pre-eject drive motor (M2) <br>\u2022 Trail edge stopper home sensor (PS31) <br>\u2022 FS control board (FSCB) <\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"50726F636564757265\">&nbsp;Procedure<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E204653353336206F72204653353336534420697320696E7374616C6C6564\">&nbsp;When FS-536 or FS-536SD is installed<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between M9-relay CN7&lt;A>-FSCB J13 for proper connection, and correct as necessary.<\/li><li>Check the connector of M9 for proper drive coupling and correct as necessary.<\/li><li>Check the connector between PS21-relay CN8-relay CN7&lt;B>-FSCB J12 for proper connection, and correct as necessary.<\/li><li>Check the connector between PS22-relay CN8-relay CN7&lt;B>-FSCB J12 for proper connection, and correct as necessary.<\/li><li>PS21 I\/O check, sensor check<ul><li>Control signal: FSCB J12-6 (ON)<\/li><li>Location of electrical component: FS-536\/FS-536SD 7-C<\/li><\/ul><\/li><li>PS22 I\/O check, sensor check<ul><li>Control signal: FSCB J12-9 (ON)<\/li><li>Location of electrical component: FS-536\/FS-536SD 7-C<\/li><\/ul><\/li><li>M9 operation check<ul><li>Control signal: FSCB J13-3 to 4<\/li><li>Location of electrical component: FS-536\/FS-536SD 9-C<\/li><\/ul><\/li><li>Replace M9. (Part# A87GPP1500)<\/li><li>Replace FSCB. (Part# A87GPP0V00)<\/li><\/ol>\n\n\n\n<p>NOTICE<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC368Service\/en-US\/37547087474504104971.html\">FS-536\/FS-536SD<\/a>)<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E204653353337206F72204653353337534420697320696E7374616C6C6564\">&nbsp;When FS-537 or FS-537SD is installed<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between M2-relay CN1&lt;A>-FSCB J22 for proper connection and correct as necessary.<\/li><li>Check the connector of M2 for proper drive coupling and correct as necessary.<\/li><li>Check the connector between PS31-relay CN2-relay CN1&lt;B>-FSCB J22 for proper connection, and correct as necessary.<\/li><li>PS31 I\/O check, sensor check<ul><li>Control signal: FSCB J22&lt;B>-13<\/li><li>Location of electrical component: FS-537\/FS-537SD 3-D<\/li><\/ul><\/li><li>M2 operation check<ul><li>Control signal: FSCB J22&lt;A>-3 to 4<\/li><li>Location of electrical component: FS-537\/FS-537SD 1-D<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC368Service\/en-US\/37378850674501676043.html\">Replace M2.<\/a> (Part# A87HPPAF00)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC368Service\/en-US\/37378780274501675531.html\">Replace FSCB.<\/a> (Part# A87HPP9M01)<\/li><\/ol>\n\n\n\n<p>NOTICE<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC368Service\/en-US\/37546805874504157835.html\">FS-537\/FS-537SD<\/a>)<\/li><\/ul>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a rel=\"noreferrer noopener\" href=\"http:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC368Service\/en-US\/4484657419.html\" target=\"_blank\">K.3.10.26<\/a> (Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type C1144: Pre-eject drive motor drive malfunction Rank B Trouble detection condition &lt;When FS-536 or FS-536SD is installed&gt; \u2022The pre-eject home sensor (PS21) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed after the pre-eject drive motor (M9) is turned ON. \u2022 The pre-eject away &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c1144-bizhub-c658-c558-c458\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C1144 (bizhub C658\/C558\/C458)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[24],"epkb_post_type_1_tag":[],"class_list":["post-243","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c1-c658-c558-c458"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/243","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=243"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/243\/revisions"}],"predecessor-version":[{"id":244,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/243\/revisions\/244"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=243"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=243"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=243"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}