{"id":25249,"date":"2023-09-25T19:52:57","date_gmt":"2023-09-25T19:52:57","guid":{"rendered":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=25249"},"modified":"2023-12-13T14:36:09","modified_gmt":"2023-12-13T14:36:09","slug":"93-10-bizhub-950i-850i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=93-10-bizhub-950i-850i","title":{"rendered":"93-10 (bizhub 950i\/850i)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Contents<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td>JAM type<\/td><td colspan=\"2\">Misfeed at duplex transport section<\/td><\/tr><tr><td>JAM code<\/td><td colspan=\"2\">93-10<\/td><\/tr><tr><td rowspan=\"5\">JAM detection timing<\/td><td>93-10<\/td><td>The ADU paper passage sensor\/2 (PS48) is not turned ON even after the lapse of a given period of time after the leading edge of the paper has turned ON the ADU paper passage sensor\/1 (PS47).<\/td><\/tr><tr><td>&#8211;<\/td><td>Paper jam of a sheet of paper left at the duplex transport section results, if the ADU paper passage sensor\/1 (PS47) is turned ON, or the ADU paper passage sensor\/2 (PS48) is turned ON (blocked) when the main power switch ON turned ON, a door is opened and closed, or a misfeed or malfunction is reset.<\/td><\/tr><tr><td>&#8211;<\/td><td>Paper jam of a sheet of paper left at the duplex transport section results, if the main power switch is turned ON, the ADU paper passage sensor\/1 (PS47) is turned ON.<\/td><\/tr><tr><td>&#8211;<\/td><td>Paper jam of a sheet of paper left at the duplex transport section results, if the main power switch is turned ON, the ADU paper passage sensor\/2 (PS48) is turned ON.<\/td><\/tr><tr><td>&#8211;<\/td><td>Paper jam of a sheet of paper left at the duplex transport section results, if a sheet of paper is determined to exist at a position detected when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset.<\/td><\/tr><tr><td>Misfeed processing location<\/td><td colspan=\"2\">-Right door<br>-Automatic duplex unit door<\/td><\/tr><tr><td>Relevant parts<\/td><td colspan=\"2\">-ADU transport motor\/1 (M31)<br>-ADU transport motor\/2 (M32)<br>-ADU paper passage sensor\/1 (PS47)<br>-ADU paper passage sensor\/2 (PS48)<br>-Paper feed\/transport drive board (PFTDB)<br>-Base board (BASEB)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Procedure<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>Step<\/th><th>Action<\/th><th>Control signal<\/th><th>Location of electrical component<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/6369798795.html\">Initial check items<\/a><\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>PS47 I\/O check, sensor check<\/td><td>PFTDB CN28-3 (ON)<\/td><td>2-P<\/td><\/tr><tr><td>3<\/td><td>PS48 I\/O check, sensor check<\/td><td>PFTDB CN28-6 (ON)<\/td><td>3-P<\/td><\/tr><tr><td>4<\/td><td>M31 load check<br><br>-Check code: 85<br><br>-Multi code: 1, 2, 3, 4<\/td><td>PFTDB CN28-14 to 17<\/td><td>4-P<\/td><\/tr><tr><td>5<\/td><td>M32 load check<br><br>-Check code: 85<br><br>-Multi code: 5, 6, 7, 8<\/td><td>PFTDB CN28-10 to 13<\/td><td>3-P<\/td><\/tr><tr><td>6<\/td><td>PFTDB F25 conduction check.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>7<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12635162123.html\">Replace PFTDB.<\/a><\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>8<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12637662987.html\">Replace BASEB.<\/a><\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12582644235.html\">(Link to the Field Service Manual)<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. Contents JAM type Misfeed at duplex transport section JAM code 93-10 JAM detection timing 93-10 The ADU paper passage sensor\/2 (PS48) is not turned ON even after the lapse of a given period of &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=93-10-bizhub-950i-850i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;93-10 (bizhub 950i\/850i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1425],"epkb_post_type_1_tag":[],"class_list":["post-25249","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-9-950i-850i-jam"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/25249","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=25249"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/25249\/revisions"}],"predecessor-version":[{"id":25250,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/25249\/revisions\/25250"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=25249"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=25249"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=25249"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}