{"id":25503,"date":"2023-10-03T13:37:04","date_gmt":"2023-10-03T13:37:04","guid":{"rendered":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=25503"},"modified":"2023-12-13T14:32:20","modified_gmt":"2023-12-13T14:32:20","slug":"c3101c3103-bizhub-950i-850i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c3101c3103-bizhub-950i-850i","title":{"rendered":"C3101,C3103 (bizhub 950i\/850i)"},"content":{"rendered":"\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Contents<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td>Trouble type<\/td><td>&#8211; C3101: Pressure roller pressure failure<br><br>&#8211; C3103: Pressure roller release failure<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>C3101:<br>&#8211; The fusing pressure home sensor (PS59) is not turned ON (pressed) even after the lapse of a predetermined period of time after the pressure operation of the pressure roller has started.<br><br>&#8211; The fusing pressure home sensor (PS59) is not turned ON (pressed) when the pressure operation of the pressure roller is complete.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>C3103:<br>&#8211; The fusing pressure home sensor (PS59) is not turned OFF (retracted) even after the lapse of a predetermined period of time after the retraction operation of the pressure roller has started.<br><br>&#8211; The fusing pressure home sensor (PS59) is not turned OFF (retracted) when the retraction operation of the pressure roller is complete.<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>&#8211; Fusing unit<br>&#8211; Fusing pressure home sensor (PS59)<br>&#8211; Fusing pressure motor (M29)<br>&#8211; CPU board (CPUB)<br>&#8211; Base board (BASEB)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Procedure<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Check the connector between M29-BASEB CN62E for proper connection and correct as necessary.<\/li>\n\n\n\n<li>Check the connector of M29 for proper drive coupling and correct as necessary.<\/li>\n\n\n\n<li>Check the connector between the fusing unit-relay CN807-BASEB CN30E for proper connection and correct as necessary.<\/li>\n\n\n\n<li>Check CPUB for proper installation and correct as necessary.<\/li>\n\n\n\n<li>PS59 I\/O check\n<ul class=\"wp-block-list\">\n<li>Control signal: BASEB CN30E-9 (ON)<\/li>\n\n\n\n<li>Location of electrical component: 8-C<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>M29 load check\n<ul class=\"wp-block-list\">\n<li>Check code: 45<\/li>\n\n\n\n<li>Multi code: 7, 8, 9<\/li>\n\n\n\n<li>Control signal: BASEB CN62E-1 to 4<\/li>\n\n\n\n<li>Location of electrical component: 8-K<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12635618699.html\">Replace M29.<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/6351365899.html\">Replace the fusing unit.<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12637720971.html\">Replace CPUB.<\/a><\/li>\n\n\n\n<li>BASEB F16E conduction check.<\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12637662987.html\">Replace BASEB.<\/a><\/li>\n<\/ol>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12611067659.html\">(Link to the Field Service Manual<\/a>)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. Contents Trouble type &#8211; C3101: Pressure roller pressure failure &#8211; C3103: Pressure roller release failure Rank B Trouble detection condition C3101:&#8211; The fusing pressure home sensor (PS59) is not turned ON (pressed) even after &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c3101c3103-bizhub-950i-850i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C3101,C3103 (bizhub 950i\/850i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1429],"epkb_post_type_1_tag":[],"class_list":["post-25503","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c3-950i-850i-trouble"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/25503","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=25503"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/25503\/revisions"}],"predecessor-version":[{"id":25504,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/25503\/revisions\/25504"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=25503"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=25503"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=25503"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}