{"id":25865,"date":"2023-10-09T18:27:57","date_gmt":"2023-10-09T18:27:57","guid":{"rendered":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=25865"},"modified":"2023-12-13T14:09:10","modified_gmt":"2023-12-13T14:09:10","slug":"c760c-bizhub-950i-850i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c760c-bizhub-950i-850i","title":{"rendered":"C760C (bizhub 950i\/850i)"},"content":{"rendered":"\n<p><strong><strong> Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Contents<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td>Trouble type<\/td><td>C760C: Power line A12 error<\/td><\/tr><tr><td>Rank<\/td><td>C<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>The fuse detection unit detected an error for a predetermined time.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>&#8211; Ozone ventilation fan (FM6)<br>&#8211; Paper cooling fan\/in (FM12)<br>&#8211; Fusing power supply cooling fan (FM10)<br>&#8211; DC power supply cooling fan (FM9)<br>&#8211; Paper cooling fan\/out (FM13)<br>&#8211; Tucking fan\/Md (FM101)<br>&#8211; Tucking fan\/Rr (FM102)<br>&#8211; Tucking fan\/Fr (FM103)<br>&#8211; Total counter (TCT) (Not included)<br>&#8211; Dehumidifier drive board (DEDB)Key counter (KCT)<br>&#8211; Toner suction fan (FM7)<br>&#8211; Toner cartridge cooling fan\/1 (FM8)<br>&#8211; Base board (BASEB)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Procedure<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>BASEB F6E conduction check.<\/li>\n\n\n\n<li>Check the connector between FM6-relay CN322-BASEB CN27E for proper connection and correct as necessary.<\/li>\n\n\n\n<li>Check the connector between FM12-relay CN325-BASEB CN27E for proper connection and correct as necessary.<\/li>\n\n\n\n<li>Check the connector between FM10-relay CN803-BASEB CN23E for proper connection and correct as necessary.<\/li>\n\n\n\n<li>Check the connector between FM9-relay CN333-BASEB CN23E for proper connection and correct as necessary.<\/li>\n\n\n\n<li>Check the connector between FM13-relay CN323-BASEB CN27E for proper connection and correct as necessary.<\/li>\n\n\n\n<li>Check the connector between FM101-relay CN337-relay CN334-BASEB CN25E for proper connection and correct as necessary.<\/li>\n\n\n\n<li>Check the connector between FM102-relay CN335-relay CN334-BASEB CN25E for proper connection and correct as necessary.<\/li>\n\n\n\n<li>Check the connector between FM103-relay CN336-relay CN334-BASEB CN25E for proper connection and correct as necessary.<\/li>\n\n\n\n<li>Check the connector between TCT-relay CN702-BASEB CN27E for proper connection and correct as necessary. (Not included)<\/li>\n\n\n\n<li>Check the connector between DEDB CN2-relay CN601-BASEB CN23E for proper connection and correct as necessary.<\/li>\n\n\n\n<li>Check the connector between KCT-relay CN615-BASEB CN23E for proper connection and correct as necessary.<\/li>\n\n\n\n<li>Check the connector between FM7-relay CN326-BASEB CN24E for proper connection and correct as necessary.<\/li>\n\n\n\n<li>Check the connector between FM8-relay CN522-BASEB CN24E for proper connection and correct as necessary.<\/li>\n\n\n\n<li>FM6 load check\n<ul class=\"wp-block-list\">\n<li>Check code: 42<\/li>\n\n\n\n<li>Multi code: 11, 12<\/li>\n\n\n\n<li>Control signal: BASEB CN27E-7 to 9<\/li>\n\n\n\n<li>Location of electrical component: 13-C<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12635771787.html\">Ozone ventilation fan (FM6)<\/a><\/li>\n\n\n\n<li>FM12 load check\n<ul class=\"wp-block-list\">\n<li>Check code: 42<\/li>\n\n\n\n<li>Multi code: 18, 19<\/li>\n\n\n\n<li>Control signal: BASEB CN27E-4 to 6<\/li>\n\n\n\n<li>Location of electrical component: 13-C<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12635833227.html\">Paper cooling fan\/in (FM12)<\/a><\/li>\n\n\n\n<li>FM10 load check\n<ul class=\"wp-block-list\">\n<li>Check code: 42<\/li>\n\n\n\n<li>Multi code: 27, 33<\/li>\n\n\n\n<li>Control signal: BASEB CN23E-10 to 12<\/li>\n\n\n\n<li>Location of electrical component: 10-K<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12638188683.html\">Fusing power supply cooling fan (FM10)<\/a><\/li>\n\n\n\n<li>FM9 load check\n<ul class=\"wp-block-list\">\n<li>Check code: 42<\/li>\n\n\n\n<li>Multi code: 9, 10<\/li>\n\n\n\n<li>Control signal: BASEB CN23E-7 to 9<\/li>\n\n\n\n<li>Location of electrical component: 9-K<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12635802507.html\">DC power supply cooling fan (FM9)<\/a><\/li>\n\n\n\n<li>FM13 load check\n<ul class=\"wp-block-list\">\n<li>Check code: 42<\/li>\n\n\n\n<li>Multi code: 13<\/li>\n\n\n\n<li>Control signal: BASEB CN27E-10 to 12<\/li>\n\n\n\n<li>Location of electrical component: 14-C<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12635843467.html\">Paper cooling fan\/out (FM13)<\/a><\/li>\n\n\n\n<li>FM101 load check\n<ul class=\"wp-block-list\">\n<li>Check code: 42<\/li>\n\n\n\n<li>Multi code: 22<\/li>\n\n\n\n<li>Control signal: BASEB CN25E-1 to 3<\/li>\n\n\n\n<li>Location of electrical component: 7-K<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/11293419147.html\">Tucking fan\/Md (FM101), Tucking fan\/Rr (FM102), Tucking fan\/Fr (FM103)<\/a><\/li>\n\n\n\n<li>FM102 load check\n<ul class=\"wp-block-list\">\n<li>Check code: 42<\/li>\n\n\n\n<li>Multi code: 23<\/li>\n\n\n\n<li>Control signal: BASEB CN25E-7, 8<\/li>\n\n\n\n<li>Location of electrical component: 7-K<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/11293419147.html\">Tucking fan\/Md (FM101), Tucking fan\/Rr (FM102), Tucking fan\/Fr (FM103)<\/a><\/li>\n\n\n\n<li>FM103 load check\n<ul class=\"wp-block-list\">\n<li>Check code: 42<\/li>\n\n\n\n<li>Multi code: 23<\/li>\n\n\n\n<li>Control signal: BASEB CN25E-4, 5<\/li>\n\n\n\n<li>Location of electrical component: 7-K<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/11293419147.html\">Tucking fan\/Md (FM101), Tucking fan\/Rr (FM102), Tucking fan\/Fr (FM103)<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12635192843.html\">Dehumidifier drive board (DEDB)<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/6367482891.html\">Replace the key counter.<\/a><\/li>\n\n\n\n<li>FM7 load check\n<ul class=\"wp-block-list\">\n<li>Check code: 42<\/li>\n\n\n\n<li>Multi code: 1<\/li>\n\n\n\n<li>Control signal: BASEB CN24E-4 to 6<\/li>\n\n\n\n<li>Location of electrical component: 1-K<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12635782027.html\">Toner suction fan (FM7)<\/a><\/li>\n\n\n\n<li>FM8 load check\n<ul class=\"wp-block-list\">\n<li>Check code: 42<\/li>\n\n\n\n<li>Multi code: 24<\/li>\n\n\n\n<li>Control signal: BASEB CN24E-1 to 3<\/li>\n\n\n\n<li>Location of electrical component: 1-K<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12635792267.html\">Toner cartridge cooling fan\/1 (FM8)<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12637662987.html\">Base board (BASEB)<\/a><\/li>\n<\/ol>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12613373963.html\">(Link to the Field Service Manual)<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. Contents Trouble type C760C: Power line A12 error Rank C Trouble detection condition The fuse detection unit detected an error for a predetermined time. Trouble isolation &#8211; Relevant electrical parts &#8211; Ozone ventilation fan &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c760c-bizhub-950i-850i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C760C (bizhub 950i\/850i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1433],"epkb_post_type_1_tag":[],"class_list":["post-25865","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c7-950i-850i-trouble"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/25865","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=25865"}],"version-history":[{"count":2,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/25865\/revisions"}],"predecessor-version":[{"id":25878,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/25865\/revisions\/25878"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=25865"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=25865"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=25865"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}