{"id":25912,"date":"2023-10-10T14:30:09","date_gmt":"2023-10-10T14:30:09","guid":{"rendered":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=25912"},"modified":"2023-12-13T14:09:10","modified_gmt":"2023-12-13T14:09:10","slug":"c762a-bizhub-950i-850i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c762a-bizhub-950i-850i","title":{"rendered":"C762A (bizhub 950i\/850i)"},"content":{"rendered":"\n<p><strong><strong> Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Contents<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td>Trouble type<\/td><td>C762A: Power line B10 error<\/td><\/tr><tr><td>Rank<\/td><td>C<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>The fuse detection unit detected an error for a predetermined time.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>&#8211; Tray 1 paper feed clutch (CL1)<br>&#8211; Tray 2 paper feed clutch (CL2)<br>&#8211; Tray 3 paper feed clutch (CL5)<br>&#8211; Tray 3 transport clutch (CL6)<br>&#8211; Horizontal transport clutch (CL3)<br>&#8211; Tray 4 paper feed clutch (CL7)<br>&#8211; Tray 3 lift-up motor (M23)<br>&#8211; Tray 4 lift-up motor (M24)<br>&#8211; Paper feed\/transport drive board (PFTDB)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Procedure<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>PFTDB F23 conduction check.<\/li>\n\n\n\n<li>Check the connector between CL1-relay CN151-relay CN145B-PFTDB CN14 for proper connection and correct as necessary.<\/li>\n\n\n\n<li>Check the connector between CL2-relay CN156-relay CN155A-PFTDB CN12 for proper connection and correct as necessary.<\/li>\n\n\n\n<li>Check the connector between CL5-relay CN985-relay CN118-relay CN113A-PFTDB CN16 for proper connection and correct as necessary.<\/li>\n\n\n\n<li>Check the connector between CL6-relay CN119-relay CN193-relay CN113B-PFTDB CN17 for proper connection and correct as necessary.<\/li>\n\n\n\n<li>Check the connector between CL3-relay CN131-relay CN143-PFTDB CN15 for proper connection and correct as necessary.<\/li>\n\n\n\n<li>Check the connector between CL7-relay CN986-relay CN123-relay CN121A-PFTDB CN18 for proper connection and correct as necessary.<\/li>\n\n\n\n<li>Check the connector between M23-PFTDB CN15 for proper connection and correct as necessary.<\/li>\n\n\n\n<li>Check the connector between M24-PFTDB CN15 for proper connection and correct as necessary.<\/li>\n\n\n\n<li>CL1 load check\n<ul class=\"wp-block-list\">\n<li>Check code: 20<\/li>\n\n\n\n<li>Multi code: 1<\/li>\n\n\n\n<li>Control signal: PFTDB CN14-14, 15<\/li>\n\n\n\n<li>Location of electrical component: 13-P<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12635679883.html\">Replace CL1.<\/a><\/li>\n\n\n\n<li>CL2 load check\n<ul class=\"wp-block-list\">\n<li>Check code: 20<\/li>\n\n\n\n<li>Multi code: 2<\/li>\n\n\n\n<li>Control signal: PFTDB CN12-1, 2<\/li>\n\n\n\n<li>Location of electrical component: 1-P<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12635690123.html\">Replace CL2.<\/a><\/li>\n\n\n\n<li>CL5 load check\n<ul class=\"wp-block-list\">\n<li>Check code: 20<\/li>\n\n\n\n<li>Multi code: 3<\/li>\n\n\n\n<li>Control signal: PFTDB CN16-5, 6<\/li>\n\n\n\n<li>Location of electrical component: 5-X<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12635710603.html\">Replace CL5.<\/a><\/li>\n\n\n\n<li>CL6 load check\n<ul class=\"wp-block-list\">\n<li>Check code: 21<\/li>\n\n\n\n<li>Multi code: 1<\/li>\n\n\n\n<li>Control signal: PFTDB CN17-10, 11<\/li>\n\n\n\n<li>Location of electrical component: 6-X<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12635720843.html\">Replace CL6.<\/a><\/li>\n\n\n\n<li>CL3 load check\n<ul class=\"wp-block-list\">\n<li>Check code: 21<\/li>\n\n\n\n<li>Multi code: 2<\/li>\n\n\n\n<li>Control signal: PFTDB CN15-5, 6<\/li>\n\n\n\n<li>Location of electrical component: 9-X<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12635700363.html\">Replace CL3.<\/a><\/li>\n\n\n\n<li>CL7 load check\n<ul class=\"wp-block-list\">\n<li>Check code: 20<\/li>\n\n\n\n<li>Multi code: 4<\/li>\n\n\n\n<li>Control signal: PFTDB CN18-2, 3<\/li>\n\n\n\n<li>Location of electrical component: 7-X<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12635731083.html\">Replace CL7.<\/a><\/li>\n\n\n\n<li>M23 load check\n<ul class=\"wp-block-list\">\n<li>Check code: 23<\/li>\n\n\n\n<li>Multi code: 6<\/li>\n\n\n\n<li>Control signal: PFTDB CN15-3, 4<\/li>\n\n\n\n<li>Location of electrical component: 9-X<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12635525771.html\">Replace M23.<\/a><\/li>\n\n\n\n<li>M24 load check\n<ul class=\"wp-block-list\">\n<li>Check code: 23<\/li>\n\n\n\n<li>Multi code: 7<\/li>\n\n\n\n<li>Control signal: PFTDB CN15-1, 2<\/li>\n\n\n\n<li>Location of electrical component: 9-X<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12635536011.html\">Replace M24.<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12635162123.html\">Replace PFTDB.<\/a><\/li>\n<\/ol>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12620968331.html\">(Link to the Field Service Manual)<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. Contents Trouble type C762A: Power line B10 error Rank C Trouble detection condition The fuse detection unit detected an error for a predetermined time. Trouble isolation &#8211; Relevant electrical parts &#8211; Tray 1 paper &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c762a-bizhub-950i-850i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C762A (bizhub 950i\/850i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1433],"epkb_post_type_1_tag":[],"class_list":["post-25912","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c7-950i-850i-trouble"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/25912","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=25912"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/25912\/revisions"}],"predecessor-version":[{"id":25914,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/25912\/revisions\/25914"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=25912"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=25912"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=25912"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}