{"id":26012,"date":"2023-10-13T11:03:51","date_gmt":"2023-10-13T11:03:51","guid":{"rendered":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=26012"},"modified":"2023-12-13T14:05:37","modified_gmt":"2023-12-13T14:05:37","slug":"c6f01c6f02c6f03c6f04c6f05c6f06c6f08c6f07c6f08c6f09c6f0ac6fcdc6fdd-bizhub-950i-850i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c6f01c6f02c6f03c6f04c6f05c6f06c6f08c6f07c6f08c6f09c6f0ac6fcdc6fdd-bizhub-950i-850i","title":{"rendered":"C6F01,C6F02,C6F03,C6F04,C6F05,C6F06,C6F08,C6F07,C6F08,C6F09,C6F0A,C6FCD,C6FDD (bizhub 950i\/850i)"},"content":{"rendered":"\n<p><strong><strong> Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Contents<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td>Trouble type<\/td><td>&#8211; C6F01: Scanner sequence trouble 1<br><br>&#8211; C6F02: Scanner sequence trouble 2<br><br>&#8211; C6F03: Scanner sequence trouble 3<br><br>&#8211; C6F04: Scanner sequence trouble 4<br><br>&#8211; C6F05: Scanner sequence trouble 5<br><br>&#8211; C6F06: Scanner sequence trouble 6<br><br>&#8211; C6F07: Scanner sequence trouble 7<br><br>&#8211; C6F08: Scanner sequence trouble 8<br><br>&#8211; C6F09: Scanner sequence trouble 9<br><br>&#8211; C6F0A: Scanner sequence trouble 10<br><br>&#8211; C6FDC: Scanner sequence trouble DC<br><br>&#8211; C6FDD: Scanner sequence trouble DD<\/td><\/tr><tr><td>Rank<\/td><td>&#8211; C6F01 to C6F0A: C<br>&#8211; C6FDC, C6FDD: B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>The original transport interval becomes shorter than the predetermined value due to an original transport control error in original reading in DF.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>Scanner<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>&#8211; CPU board (CPUB)<br>&#8211; Base board (BASEB)<br>&#8211; DF control board (DFCB)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Procedure<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Correct the harness connection between main body and DF if faulty.<\/li>\n\n\n\n<li>Check CPUB for proper installation and correct as necessary.<\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/6224208139.html\">Replace DFCB.<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12637720971.html\">Replace CPUB.<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12637662987.html\">Replace BASEB.<\/a><\/li>\n<\/ol>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub950iService\/en-US\/12612208139.html\">(Link to the Field Service Manual) <\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers. Contents Trouble type &#8211; C6F01: Scanner sequence trouble 1 &#8211; C6F02: Scanner sequence trouble 2 &#8211; C6F03: Scanner sequence trouble 3 &#8211; C6F04: Scanner sequence trouble 4 &#8211; C6F05: Scanner sequence trouble 5 &#8211; &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c6f01c6f02c6f03c6f04c6f05c6f06c6f08c6f07c6f08c6f09c6f0ac6fcdc6fdd-bizhub-950i-850i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C6F01,C6F02,C6F03,C6F04,C6F05,C6F06,C6F08,C6F07,C6F08,C6F09,C6F0A,C6FCD,C6FDD (bizhub 950i\/850i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1432],"epkb_post_type_1_tag":[],"class_list":["post-26012","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c6-950i-850i-trouble"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/26012","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=26012"}],"version-history":[{"count":2,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/26012\/revisions"}],"predecessor-version":[{"id":26159,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/26012\/revisions\/26159"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=26012"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=26012"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=26012"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}